Kudos Pro UHD1000
System Operation
Issue 1 Rev 2
Page 37
© 2016 SAM
Video Index
Configures Video Index (VI) signaling. Available controls are:
Line 23
Configures Line 23 (L23) signaling. Available controls are:
Note:
In the SD domain, take care to avoid a line clash if embedded VITC and SMPTE 2016 are
both enabled.
In the event of both VITC and SMPTE being required:
•
For SD 625 signals, SMPTE2016 is relocated to the line before the VITC line, i.e. if
VITC is at default 19 and 21, SMPTE2016 will be placed on either 18 or 20
respectively when there is a clash.
•
For SD 525 signals, SMPTE2016 is relocated to the line between the two VITC
lines, i.e. if default VITC is on lines 14 and 16, SMPTE2016 will be placed on line
15 in the event of a clash.
Control
Options
VI mode
•
Auto
(default): Automatically sets the conversion based on a
combination of the input and output standards.
•
Pass
: Passes VI information through the unit unchanged.
•
Force
: Forces the conversion specified on the output.
•
Delete
: Deletes VI information from the output signal.
Out format
•
SMPTE
(default): Outputs Video Index information according
to SMPTE RP186.
•
AFD
: Outputs Video Index information according to
ARDSPEC1
VI pass data
•
Off
(default): VI data other than coded frame and AFD are
blanked
•
On
: User data from the source VI are passed from the input to
the output.
Control
Options
L23 mode
•
Auto
(default) - Automatically sets the conversion based on a
combination of the input and output standards.
•
Pass
- Passes L23 information through the unit unchanged.
•
Force
- Forces the conversion specified on the output.
•
Delete
- Deletes L23 information from the output signal.
L23 out format
•
ETSI
(default) - Outputs L23 information according to ETSI
EN 300 294 v1.4.1.
•
AFD
- Outputs L23 information according to West Country
TV/HTV/Central TV L23_SPEC.doc 1997.
In line
Selects the input line from which the L23 information is read. The
range is from line 10 to line 23 in one-line steps.
Default = line 23