
80 PRO-LINK
®
Edge Hardware and Software User’s Manual
Chapter
4
• Using the Diagnostics Menu
Calibrating a Datapoint
When you select a datapoint to calibrate the PRO-LINK
®
Edge immediately starts
the calibration process for that datapoint.
NOTE:
i
Each calibration screen is unique to the type of module and the type of cal-
ibration being performed. In addition, some applications (e.g., CAT
®
ACERT™) do not include the Program button.
To calibrate a datapoint:
Figure 4.23
List of Datapoints for the Cruise Control Category
1
Touch the screen to select the datapoint you want to calibrate (e.g.,
Cruise
Control Vehicle Speed High Limit
).
NOTE:
i
Not all datapoints will be available for calibration (i.e., they are grayed out).
Datapoints can be unavailable because the datapoint is read-only (i.e.,
non programmable), or, in some applications, due to password level
protections.