background image

200/300 Series

 — VTC eLock Instructions

6

iCLASS or Magstripe credentials). 

EXITING PASSAGE MODE 

will flash on the LCD and the latch bolt will extend. 

Methods to begin building 

a database of eLocks in 

LockView Software

Note: Supervisor, User and parameter changes that already 

exist in the eLock will automatically be carried into 

LockView once the eLock has been enrolled.

For Networked (802.11g or Ethernet) eLocks, please follow 

the 

eLock Database & Network Configuration & Install 

Manual

 and the 

LockView NTC/VTC Software Instruction 

Manual

 before proceeding.

LockView Mode Instructions

(For complete details on how to build a database of 

users and eLocks, see the 

LockView NTC/VTC Software 

Instruction Manual

 and 

eLock Manual Programming Guide

)

LockView NTC/VTC Software v4 must be installed and the 

eLock must be in 

SETUP

 mode before continuing. (See 

Setup Code section on page 10.)

Stand-alone eLocks (Direct USB connection to laptop 

computer with LockView is required) 

There are two methods 

that can be used to add eLocks to the LockView software.

Automatic Method

1.  With the eLock in 

SETUP

 mode, connect the eLock via the 

USB cable to the computer on which LockView is installed.

2.  Login to LockView.

3.  After 30 seconds, the below will appear.

NOTE: After 5 minutes of inactivity, the eLock will exit 

SETUP

 

mode.

4. Click 

Yes

.

5.  The below will appear. Type in the name of the lock. 

**Once a Lock Name has been chosen in LockView, it can 

not be changed. Please be sure the name that is chosen is 

the one that will be used in the future.

6. Click 

Save

 when done.

7.  Go to 

Lock Editor 

tab in 

Lock/User Editor

.

8.  Left click to highlight the name of the lock and then click 

Edit 

Lock

.

9.  Verify and/or adjust all other lock parameters. (

See LockView 

NTC/VTC Soft

ware Instruction Manual 

for complete 

details.

)

10. Click 

OK

 when done.

Manual Method

1.  Login to LockView.

2.  Go to 

Lock/User Editor

Lock Editor 

tab and click 

Add Lock

.

3.  Enter the required information: 

Lock Name

Lock Serial 

Number 

and 

Setup Code 

(supplied on green sticker set as 

Setup Cd).

**Once the Lock Name has been chosen in LockView, it can 

not be changed. Please be sure the name that is chosen is 

the one that will be used in the future.

4.  Verify and/or adjust all other lock parameters and click 

OK

(

See 

LockView NTC/VTC Software Instruction Manual 

for 

complete details on these options

)

5.  With the eLock in 

SETUP

 mode, connect the eLock via the 

USB cable to the computer on which LockView is installed.

6.  After 30 seconds, the lock will be updated in LockView. Click 

Refresh

 to prompt the update.

NOTE: After 5 minutes of inactivity, the eLock will exit 

SETUP

 

mode.

200/300 Series 

VTC eLock — Instructions 

continued

Summary of Contents for Level 5 VTC eLock 200 Series

Page 1: ...worked and stand alone eLocks please see the Help section in LockView NTC VTC Software v4 1 Dot matrix LCD 2 Network button blue LED 3 UP button 4 NEXT SELECT button 5 BACK CANCEL button 6 MENU button 7 DOWN button 8 Button 9 Button 10 Low battery indicator yellow LED 11 Magstripe reader location if equipped 12 HID Prox or HID iCLASS reader location if equipped 13 ENTER button 14 CLEAR button 15 A...

Page 2: ...ponents Front view eLock controller Back view VTC eLock controller Battery cable connector Integrated Wi Fi antenna cable included for 300 Series Wi Fi version 200 300 Series VTC eLock Components 9V Battery Jumper Port USB Port for direct connection to LockView software ...

Page 3: ...not included 2 Wi Fi antenna cable connector or Ethernet connector Wi Fi connector shown 300 Series only 3 Control module battery cable connector 4 2 5 mm AC adapter plug in adapter not included 5 Ground terminal 6 Dual eLatch connector Latch 2 if equipped one latch is included 7 Latch connector Latch 1 one latch is included 8 Battery pack cover 6 AA batteries not included ...

Page 4: ...ypes To clean the surface of the eLock apply non acid based cleaner to a clean cotton cloth do not spray cleaner directly on the eLock Wipe down keypad and housing taking care around the beeper opening and edges of keypads Wipe excess cleaner off of all surfaces Setting up the eLock Getting Started Out of the Box If the eLock is stand alone 200 Series direct connection via USB to LockView NTC VTC ...

Page 5: ...Passage Mode has been activated in the eLock To place an eLock into Passage Mode PIN CREDENTIAL 1 Enter a valid PIN between 4 14 digits and press ENTER 2 Press ENTER again HOLD OPEN will flash LOCK IS HELD OPEN will appear in the upper left hand corner of the LCD CARD CREDENTIAL If the eLock is equipped with a card reader HID Prox HID iCLASS or Magstripe 1 Present a valid card within range of the ...

Page 6: ...low will appear NOTE After 5 minutes of inactivity the eLock will exit SETUP mode 4 Click Yes 5 The below will appear Type in the name of the lock Once a Lock Name has been chosen in LockView it can not be changed Please be sure the name that is chosen is the one that will be used in the future 6 Click Save when done 7 Go to Lock Editor tab in Lock User Editor 8 Left click to highlight the name of...

Page 7: ...lphabetically by name or showing all supervisors first 6 Press UP DOWN to scroll by line or to scroll by page to highlight credential to be deleted and press NEXT SELECT 7 Press UP and NEXT SELECT to delete DELETED will be displayed when complete 8 Press BACK CANCEL to return to CREDENTIAL MENU VIEW CREDENTIAL Note There are two status levels Supervisor and User Only Supervisors are allowed to VIE...

Page 8: ...M PM or 24 HOUR M F DATE w MON SUN MM DD YY w MON SUN MMM D YY w MON SUN DD MM YY w MON SUN DD MMM YY w MON SUN YYYY MM DD 1 Press MENU LOGIN PLEASE will be displayed 2 Scan valid credential or enter 4 14 digit PIN and press ENTER 3 Press DOWN button to highlight DISPLAY FORMATS and press NEXT SELECT 4 DISPLAY FORMATTING will be displayed 5 Press UP DOWN buttons to select and buttons to adjust 6 P...

Page 9: ...ric keypad or buttons to adjust 0 MUTE 6 Press NEXT SELECT when done 7 Press BACK CANCEL to return to main menu Reset Net Schedule A PROPERLY CONFIGURED AND ENABLED NETWORK eLock IS REQUIRED TO MAKE USE OF THIS FEATURE Only Supervisors are allowed to RESET NET SCHED Using RESET NET SCHED the scheduled network check in time can be set 1 Press MENU LOGIN PLEASE will be displayed 2 Scan valid credent...

Page 10: ... and Hold NEXT SELECT to reset 8 Factory will appear in the upper left hand corner of the eLock LCD Note whenever eLock is in factory mode it is considered unsecured Stand alone Networked eLock Alarm States The eLock has programmable ALARM ALERT STATES 1 Battery Low A properly configured and enabled network eLock is required to make use of this feature Battery Low can be programmed to send an aler...

Page 11: ... used to determine Wi Fi strength and quality See LockView Manual for NOTIFIER explanation 200 300 Series VTC eLock Manual Programming continued q Add edit view and delete users supervisors and their credentials q Add edit and delete VTC eLocks q Assign access rights between users supervisors and VTC eLocks in the database q USB or network connection q Download view save print archive and delete a...

Page 12: ... Notes Part 332986000000 Copyright 2012 CompX Security Products Any companies and or products referred to herein are marks or registered trademarks of their respective companies owners and or mark holders ...

Reviews: