8
5.3 SAFETY SHUT-OFF BAR INSTALLATION
Note: The safety shut off will disconnect the power to the power pack when an
obstruction touches the padded bar or the carriages reach their maximum
extension. The safety shut off switch is factory pre-wired. Refer to Figure 4 and 5.
Note: This procedure can be done on the floor.
1. Attach the Actuator Mounting Bracket (1-1378) to the crossmember using hex head
bolt 1/4” NC x 3/4” lg. bolt (6-0178), lockwasher 1/4” dia. (6-0056), and hex nut 1/4”
NC (6-0032).
2. Attach Actuator Bar assembly to the Actuator Mounting Bracket assembly using hex
head bolt 1/4” NC x 1 1/2” lg. (6-0027), lockwasher (6-0178), and hex nut 1/4” NC
(6-0032).
3. Slide Safety Shut-Off Microswitch Assembly over open end of actuator bar and bolt
the assembly to the crossmember using hex head bolt 1/4” NC x 3/4” lg. (6-0178),
lockwasher (6-0178), and hex nut 1/4” NC (6-0032).
4.
Bolt Actuator Extension (1-1379) onto open end of actuator bar using (2x) hex head bolt
1/4” NC x 1 1/4” lg. (6-0027), lockwasher (6-0178), and hex nut 1/4” NC (6-0032).
5.4 SAFETY SHUT-OFF BAR ADJUSTMENT
Note: This procedure must be done last.
1. When the lift is fully installed, leveled. and operational, extend the carriages to their
full upper limit.
2. Lower the carriages about 1/4” to 1/2”.
3. Adjust the stopper bolt by threading the upper nut towards the head, and the lower nut
towards the bottom.
4. The bottom of the bolt should be touching the top of the carriage.
5. Tighten both stopper nuts onto the actuator bar extension.
Summary of Contents for EELR326A
Page 8: ...7 5 2 BAY LAYOUT Figure 3 Bay Layout ...
Page 10: ...9 Figure 4 Safety Shut Off Bar Installation Figure 5 Safety Shut Off Bar Power Side ...
Page 24: ...23 8 PARTS MANUAL 8 1 LIFT ASSEMBLY ...
Page 27: ...26 8 3 HYDRAULIC SYSTEM ...
Page 29: ...28 8 5 POWER PACK 6 2055 AB 1381 208 230V 1PH 60Hz ...