16
•
EEBC500B-INT-Z
18. REPLACING THE CLAMP CABLES
1.
Remove the two screws on the cover plate, and tilt it
out of the slots on the bottom.
2.
Remove the screws on the terminals using a 6 mm
hex wrench. These will be tight (torque 45-50 in-lbs.),
so you will probably need to use the long end. Take
care when removing the screws to prevent stripping
the hole. To prevent damage, it is recommended you
use an open ended wrench to keep the terminal
from spinning.
3.
The strain reliefs are held in by three spring tabs.
While pulling on the cable (opposite side of strain
relief), push on the bottom tab to get it out first, then
squeeze the two side tabs together to remove the
strain relief from the hole.
4.
Follow these steps in reverse to assemble the
new cable.