27
HYDRAULIC TUBE FITTING
It is important to be equipped with a suitable tool for cutting the tube so that the cut is carried out properly for the tube
to be inserted into the recoverable bushing.
Both the bushing and the insert must be greased or oiled
Use only original SMV tube fittings
IIN
Insert the bushing into the tube and screw tighten in an anticlockwise direction until reaching its mechanical stop. Screw
the tube fitting in a clockwise direction inside the bushing until you reach the end of thread without interruption. If the
need to modify the direction arises the tube fitting can be unscrewed to a maximum of 1 full turn.
Warning
It is absolutely necessary for this procedure to be carried out according to instructions in order to seal the tube
fitting properly.
Tighten all the tube fittings with the corresponding washers on the jacks.
You are advised to leave the length of the tubes on the power pack side, which helps make maintenance tasks easier.
Warning
Avoid narrow bends and traction on the hydraulic tube during folding of jacks.
SEALING WASHER
THE TUBE MUST REACH ITS MECHANICAL STOP