SMS ControlMate/3G © 2016-2018
Page 17 of 56
DIAL-IN EVENTS
ControlMate supports a voice-call from any authorised CLI number to
initiate any controller
command
. The command
for CLI member ‘n’
may be changed with
SET DIALIN n
{command}
Each CLI user may have a different assigned dial-in command.
The ControlMate
allows the call to ‘ring’ twice
17
, but rejects the incoming call
–
thus it is a
free
call,
however the caller w
on’t know
if the device has turned on or off
18
in response to the dial-in. If you
have SMS assigned to that event, the unit can be configured to send a confirmation of the recent
dial-in event.
When a
successful
call-in has been made, hang-up within 5 secs, and the controller will make a
return call as notification of a successful access attempt.
DO NOT ANSWER THE CALLBACK
, or the
SIM account will be charged. Reject or ignore the notification call-back, which will be dropped after
approximately 5 seconds. Call-back notifications may be disabled with
SET CALL OFF
For example,
if ‘
Out 0 Toggle
’ is configured, and
output 0 is connected to a pump, which can run
for up to an hour
…
Set the pulse duration for output 0 to hold
‘
on
’
for 1 hour… then if a caller dials in, or forgets to call
back, the pump will turn off automatically after an
hour anyway. This doesn’t help if someone else
dials in
‘
to be helpful
’
–
soon after you turned the pump on
–
as they will simply turn the pump off !
Just make sure those in the caller ID
access list know what they’re doing.
The notifications can help
reduce any confusion. If you don’t get a
call-back
–
the command may not have been executed
–
so
checking with a
SHO xxx
inquiry may be worthwhile.
Users may be added to the OUTSMS assignments for any output
–
and
they’ll
be notified by text
message whenever that relay changes state.
SETTING TIMERS
The timer capabilities are extremely flexible. There are multiple timers
–
each may be set to operate
on one or more days of the week at a specified time.
Example: To set timer #4 to toggle output relay #1 on Weekends at 17:00 (5:00pm)
–
SET TIMER 4 17:00 Wke out 1 tog
To break this down into four fields
…
SET TIMER 4
is self-explanatory
…
17:00
is the time on selected days to perform the command.
This timer is only triggered on Weekend days (
WKE
),
… and the command to be executed is
OUT 1 TOG
17
Caller-ID data is provided between the first and second incoming ring. Ensure the phone making the
incoming call is configured to
send
Caller-
ID information, or ControlMate can’t identify the caller by their
number.
18
The caller’s phone number must be correctly stored in the CLI list for a dial
-in to be successful. There is no
difference to a dial-in user if their call is accepted or rejected as being a CLI member. It is suggested in this
case that any dial-in output is configured with a
pulsed
duration, or to send an SMS back to the sender - to
avoid being acci
dentally toggled the ‘wrong’ way –
thus any dial-in call after the pulse has expired will always
set the output ‘on’ for another pulse cycle.
Summary of Contents for ControlMate
Page 2: ...SMS ControlMate 3G 2016 2018 info SL4P net Page 2 of 56 BLANK PAGE...
Page 6: ...SMS ControlMate 3G 2016 2018 info SL4P net Page 6 of 56 BLANK PAGE...
Page 9: ...SMS ControlMate 3G 2016 2018 info SL4P net Page 9 of 56 CONTROLMATE V2 LOGICAL BLOCK DIAGRAM...
Page 10: ...SMS ControlMate 3G 2016 2018 info SL4P net Page 10 of 56 BLANK PAGE...
Page 52: ...SMS ControlMate 3G 2016 2019 info SL4P net Page 52 of 56 BLANK PAGE...
Page 54: ...SMS ControlMate 3G 2016 2019 info SL4P net Page 54 of 56 BLANK PAGE...
Page 56: ...SMS ControlMate 3G 2016 2019 info SL4P net Page 56 of 56 BACK COVER...