Your settings
Menu items and submenu items
Presettings
Your settings
Default image display
HI-MAT+
Maximum zoom factor 1...16 times
8
Continuous zoom
on
Zoom interpolation
on
Screen saver after 1...30 minutes (0 = off)
0
Location menu
Location
AIRPORT
Subsite
GATE
View/monitor assignment
standard
Position main monitor
left
Audible baggage marking alarm [1...10 sec] (0 = off)
1
Buffer time in case of power failure [1...20 min]
3
Scanning functions
(
F
2-35)
Forbidden image display modes during conveyor run
Superenhancement
off
All image display modes except for Superenhance-
ment and Zoom
on
Zoom
on
Operating mode
One-way
Scanning direction
standard/forward
Reverse scanning
off
Reverse key locking
off
Forward key locking
on
Releasing conveyor keys is ignored for 0...3 seconds
0
Continuous scanning
off
For cutless images conveyor reverses at
Start
Recheck/external image evaluation
(
F
2-42)
Store images - if unsuspicious
off
Store images - if suspicious
off
Store images - after timeout
off
Maximum recheck/evaluation time [10...9999 sec]
(0 = off)
0
Image transmission method
Screen
Transmit images
on
Automatic detection
(
F
2-39)
X-ACT
on
Detection class [1...30]
1
High Density Alert HDA
on
Minimum absorption [0...100%]
95
Minimum size [0.1...10000cm²]
100
HI-SPOT
on
Minimum absorption [0...100%]
90
95587413 01/01/09 © Smiths Heimann
2-98
Summary of Contents for HI-SCAN 100100T
Page 2: ...95584681 01 01 09 Smiths Heimann ...
Page 4: ...Contents IV 95584681 01 01 09 Smiths Heimann ...
Page 5: ...95584770 01 03 2003 Smiths Heimann 1 ...
Page 6: ......
Page 10: ......
Page 117: ...95584770 01 03 2003 Smiths Heimann 2 ...
Page 118: ......
Page 122: ......