34
331432-001
GAS CONTROL VALVE/THERMOSTAT
ON/OFF
SWITCH
TEMPERATURE
SETTING DIAL
83°C
(181°F)
21°C
(70°F)
60°C
(140°F)
68°C
(155°F)
74°C
(165°F)
54°C
(130°F)
43°C
(110°F)
Figure 36
Temperature
Dial Setting
Approximate
Temperature
°C (°F)
Time to induce a 2nd
and 3rd Degree burn
to adult skin
VERY HOT
83 (181)
Less than 1 second
C
74 (165)
Less than 1 second
B
68 (155)
About 1.5 seconds
A
60 (140)
Less than 5 seconds
HOT
54 (130)
More than 30 seconds
LOW
43 (110)
Normal shower temp
VAC
21 (70)
N/A
Table 3
Note:
The temperatures indicated are approximates. The
actual temperature of the heated water may vary.
The Vacation Setting (VAC) sets the controller at
approximately 21°C (70°F). This setting is recommended
when the water heater is not in use for a long period of time.
This effectively turns the controller temperature setting
down to a temperature that prevents the water in the water
heater from freezing while still conserving energy.