26
2007
ELECTROfISHING
BOATS
WARNING – KEEP ALL PERSONNEL CLEAR OF
BOOMS AND TEST LOAD WHILE GENERATOR
RUNNING.
A. Maintain GPP settings from procedure #3.
B. Start Generator.
C. Switch the Emergency Shutdown Switch (1) to
the ON position.
D. When the red light is on, the current meter
should show amperage and the seconds counter
should be counting.
E. If there is no display in the seconds counter,
replace the “N” cell batteries in the counter
PROCEDURE #4:
TEST THE GPP'S OUTPUT
Fig. 4.1
+
+
Fig. 4.2
2
1
3
(the batteries should be replaced every 5 years).
(Figure 4.2)
F. Adjusting the percent of range (2) up to 100
percent will increase the amperage shown on
the front panel meter.
G. Set the percent of range at 50 percent.
a. Switch the Mode switch (3) from
120 PPS to 60 PPS. The amperage
should drop by 1/2.
b. Switch the Mode switch from 60
PPS to 30 PPS. The amperage
should drop again by 1/2.
c. Switch the Mode switch from 30
PPS to 15 PPS. The amperage
should drop again by 1/2.
d. Switch the Mode switch from 15
PPS to 7.5 PPS. The amperage
should drop again by 1/2.
H. Switch the Emergency Shutdown Switch to the
OFF position.
I. Switch the voltage switch to the high range.
J. Return to C and retest settings in the High
Range.
IF NO OUTPUT, RETURN CONTROL BOX TO
SRI.
Summary of Contents for ELECTROFISHING BOATS
Page 1: ...USER S MANUAL ELECTROFISHING BOATS for all SRI H and EH Model Electrofishing Boats ...
Page 17: ...15 smith root com USER s MANUAL Gas Powered Pulsator GPP OPERATION ...
Page 32: ......
Page 33: ...ELECTROFISHING BOATs Standard Boating Rules ...
Page 42: ......
Page 50: ......
Page 52: ......
Page 53: ......