24
2007
ELECTROfISHING
BOATS
A. Set Voltage Selector Switch to “OFF”.
B. Check each of the high voltage terminal
pairs on TS-0 for 120 Volts AC * (fig.
2.1) Pairs: 1&2, 3&4, 5&6, 7&8, 9&10,
and 11&12.
C. If voltage measures 120 Volts AC for
each pair, go to E.
D. If voltage measures low, check terminals
1-12 to boat ground. All terminals should
show open or high resistance (Greater
than 500 Ohms). If resistance is low,
wire insulation may be damaged and
shorting to ground.
Go to Procedure 3.
E. Switch GPP Voltage Range Switch to
“LOW”. Retest all of Procedure 2. If low
voltages are found, one or more windings
may be out of phase.
F. Switch GPP Voltage Range Switch to
“HIGH”.
Retest all of Procedure 2.
G. Measure voltages on TS-0, pins 1 to 12.
They should read 720 VAC RMS.
If Voltage Is Okay, go to Procedure 6
If voltage NOT Okay, contact SRI.
PROCEDURE #2:
TEST HIGH VOLTAGE AC OUTPUT INSIDE CONSOLE*
Generator Power to GPP Terminal Strip
DANGER HIGH VOLTAGE
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
Foot Sw.
Foot Sw.
Foot Sw.
GPP Control Strip
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TS-0
9&10
11&12
7 & 8
1 & 2
3 & 4
5 & 6
Figure 2.1
High voltage is present inside the console
while the generator is running.
Only qualified personnel should attempt
high voltage measurements.
WARNING
!
*
High voltage is present inside the console
while the generator is running.
Only qualified personnel should attempt
high voltage measurements.
WARNING
!
Summary of Contents for ELECTROFISHING BOATS
Page 1: ...USER S MANUAL ELECTROFISHING BOATS for all SRI H and EH Model Electrofishing Boats ...
Page 17: ...15 smith root com USER s MANUAL Gas Powered Pulsator GPP OPERATION ...
Page 32: ......
Page 33: ...ELECTROFISHING BOATs Standard Boating Rules ...
Page 42: ......
Page 50: ......
Page 52: ......
Page 53: ......