Adjusting the minimum – Pics. 5a – 5b
The oven thermostat is equipped with a by-pass for the minimum.
When the type of gas is changed, this setting must be changed as follows:
- remove the thermostat knob A;
- if there is a glass control panel, this must be removed by unscrewing the two holding
screws (5a);
- if there is a metal control panel, the adjustment must be made through the opening on the
left of the knob housing (5b).
Light the oven and keep it at the maximum temperature for at least 30 minutes.
Turn the thermostat knob to minimum and set the by-pass to minimum to get a reduced
but constant flame. Perform this operation with the oven door closed. Use a flat-head
screwdriver on the by-pass screw. It is sufficient to loosen the by-pass screw several turns
to adjust the minimum when changing from liquid gas to natural gas.
Important: after adjusting the burner, check that the minimum flame stays lit, testing it by
repeatedly opening and closing the oven door. If the flame goes out, adjust the by-pass
setting.
On completing the operations (replacing the injector, adjusting the air and minimum) turn
off the oven and affix the new data plate (showing the type of gas being used) replacing
the previous one and re-seal all the seals with sealing wax or similar material.