Smeg PVA140 Manual Download Page 14

 

 

 

Instructions for the user

 

 

 

32 

 

7.2

 

Lighting the burners using a safety device 

 

 
 
 
 
 
 

 

Beside each knob, the burner it controls is indicated (the example to the left 
corresponds to the front left burner). 
 
The appliance is equipped with electronic ignition. Simply press the knob and 
simultaneously turn it anticlockwise to the minimum flame symbol  , until it lights. Hold 
down the knob for about 2 seconds to keep the flame lit and to activate the safety 
device. The burner may go out when the knob is released. If this happens, repeat the 
procedure, holding the knob down for longer. 
 
When the burner is lit, the relevant activation knob will light up to indicate this. The 
knob will turn off a few seconds after it is turned to the O position or if the burner goes 
out accidentally. The knob light turns on and off gradually. 

 
 

 

 

 

If the burners should go out accidentally, after about 20 seconds the safety device will 

be tripped, cutting off the gas supply, even if the gas tap is open. 

 

 
 

7.3

 

Practical tips for using the burners 

For better burner performance and minimum gas consumption, pans with 
flat, even bases and with lids should be used, and their size should be in 
proportion to the burner (see “7.5 Pan diameters”). 
 
During cooking, in order to avoid burns or damage to the hob top, all pans 
or griddles must be positioned inside the outer edge of the hob and at a 
minimum distance of 

5-7 cm

 must be maintained from the knobs. 

 

 

7.4

 

Pan diameters 

 

 

BURNERS 

min. and max. Ø (in cm) 

 
1  Auxiliary 

 

2  Semi-rapid 
3  Rapid 
4  Ultra-rapid 

7-18 

10-24 
18-24 
20-28 

 
 

Summary of Contents for PVA140

Page 1: ...justing the minimum setting for liquid gas_______________________________28 5 8 Arrangement of the burners on the hob __________________________________28 5 9 Lubrication of gas taps _________________...

Page 2: ...NCE IS INSTALLED NEVER UNPLUG BY PULLING ON THE CABLE IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF TEST OF THE HOB FOLLOWING THE INSTRUCTIONS BELOW SHOULD THE APPLIANCE NOT FUNCTION DISCONNECT IT...

Page 3: ...n the counter top with the dimensions shown in the figure keeping a minimum distance of 100 mm from the rear edge This appliance can be installed next to walls which are higher than the hob top provid...

Page 4: ...be fixed and centred as accurately as possible To install the clips into the hob all you have to do is insert them horizontally into the appropriate space by applying light pressure fig A Then turn t...

Page 5: ...equal to or greater than 3 mm in an easily accessible position close to the appliance Avoid the use of adapters and shunts If the power cable is replaced the cross section of wires in the new cable mu...

Page 6: ...the length of the piping does not exceed 2 metres when fully extended make sure that the hoses do not come into contact with moving parts and that they are not crushed in any way 4 1 Connection to li...

Page 7: ...ted In order to replace the nozzles and adjust the burners the hob top must be removed as described below 5 1 Removing the hob top Remove all the burner components following the numerical sequence in...

Page 8: ...le tightening torque must be no more than 3 Nm Adjust the air by sliding regulator D until distance X from the table in 5 4 Primary air adjustment is reached Lock regulator D by tightening screw C Bur...

Page 9: ...as indicated in the table below and in 5 5 Primary air adjustment Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter Reduced capacity 1 100 mm W Auxiliary 1 05 73 400 Semi rapid...

Page 10: ...from the maximum to the minimum position the flame must not go out 5 7 Adjusting the minimum setting for liquid gas To adjust the minimum setting with liquid gas you must tighten the screw inside or...

Page 11: ...front panel CONTROL ZONE 4 burner hob KNOB DESCRIPTION To light the flame press the knob and at the same time turn it anticlockwise to the minimum flame symbol To adjust the flame turn the knob to th...

Page 12: ...ch rack correctly on its burner follow the instructions below Each rack must be positioned on the corresponding burner in order to guarantee proper operation Be very careful to match the different cen...

Page 13: ...are repeat the positioning procedure INCORRECT CORRECT INCORRECT CORRECT Having completed the procedures described above for each of the racks the hob will be as shown below with the rack legs arrang...

Page 14: ...b will turn off a few seconds after it is turned to the O position or if the burner goes out accidentally The knob light turns on and off gradually If the burners should go out accidentally after abou...

Page 15: ...ora n acid et ched glass hob 8 2 1 Grease Use washing up liquid and a microfibre cloth 8 2 2 Rings and encrustations Use stainless steel cream or mildly abrasive creams leave the product to act for a...

Page 16: ...hey are perfectly dry The burner pins A must be inserted in the housings B in the burner crown The holes C in the latter should be slid over the igniters and thermocouples D on the hob 8 3 4 Igniters...

Reviews: