Instructions for the installer
38
2.4.3
Connection to the gas cylinder in the internal compartment of the appliance (only on
some models)
Open the side compartment and insert a gas cylinder of
max. 15 kg. Push one end of the hose onto the hose
connector and secure it with one of the two clamps
provided. Insert the hose into the gas cylinder
compartment via the hole located at the back of the
appliance following the diagram shown to the side. Push
the other end onto the pressure regulator of the gas
cylinder; secure it in place using the second clamp
provided.
Check for any leaks using a soapy solution,
never with a flame.
For the connection between the cooker and the gas cylinder use a piece of standards-compliant
hose no less than 1.4 m in length.
2.4.4
Connection to liquid gas
Use a standards-compliant pressure regulator and carry out the connection to the gas cylinder in
accordance with the regulations in force.
Make sure that the supply pressure complies with the values indicated in the paragraph “3.2/3.3
Burner and nozzle characteristics table”.
Screw the small hose connector
F
onto the large hose connector
A
;
connect the block thus obtained to the gas connector
B
(or use the hose
connector
G
which must be connected directly to the gas connector
B
)
and place the seal
C
in between them. Push the end of the rubber hose
H
onto the hose connector
A+F
(or
G
) and onto the outlet connection of
the pressure reducer on the gas cylinder. Secure the end of the hose
H
to the hose connector
A+F
(or
G
) with the standards-compliant clamp
I
.
The hose connector
G
illustrated is not supplied with the appliance. Only use standards-compliant
hose connectors.
2.4.5
Connection with a flexible steel hose (for all types of gas)
This type of connection can be made on both built-in and free-standing
appliances. Only use standards-compliant steel hoses whose length is
no greater than 2 metres. Screw the end of the flexible hose
L
onto the
threaded ½” external gas connector
B
(ISO 228-1), with the seal
C
positioned in between them.
At the end of the installation, check for any leaks with a soapy
solution, never with a flame.