Instructions for the installer
40
3.2
Burner and nozzle characteristics table (60 cm model)
Burner
Rated
heating
capacity
(kW)
LIQUID GAS – G30/G31
30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.0
50
30
350
73 71
Semi-rapid
1.8
65
33
450
131 129
Rapid (3)
3.0
85
45
800
218 214
Rapid (5)
2.5
79
45
800
182 179
Triple crown
3.2
91
65
1500
233 229
Oven
3.2
87
50
900
233 229
Grill
2.9
87
//
//
211 207
Burner
Rated
heating
capacity
(kW)
CITY GAS – G110
8 mbar
Nozzle
diameter 1/100 mm
Reduced capacity
(W)
Auxiliary
1.0
145
350
Semi-rapid
1.8
185
450
Rapid (3)
3.0
260
800
Rapid (5)
2.5
230
800
Triple crown
3.5
290
1200
Oven
3.2
270
900
Grill
2.9
270
//
The values for city gas refer to appliances in category III 1a2H3+.
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20
20 mbar
Nozzle
diameter 1/100 mm
Reduced capacity
(W)
Auxiliary
1.0
72
350
Semi-rapid
1.8
97
450
Rapid (3)
3.0
115
800
Rapid (5)
2.5
108
800
Triple crown
3.5
133
1500
Oven
3.2
130
900
Grill
2.9
130
//
Summary of Contents for CA61VM