Instructions for the installer
39
3
ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance from the electricity supply.
The appliance is preset for
natural gas G20
(2H) at a pressure of 20 mbar. In the case of operation
with other types of gas, the burner nozzles must be changed and the minimum flame adjusted on the
gas taps. In addition, in the case of the gas oven burner, the primary air must be regulated (3.4.2
Primary air adjustment for the oven burner). To change the nozzles, proceed as described in the
following paragraphs.
3.1
Replacement of the cooking hob nozzles
1.
Extract the pan racks and remove all the caps and flame-spreader crowns;
2.
Unscrew the burner nozzles with a 7 mm socket wrench;
3.
Replace the burner nozzles according to the gas to be used (see paragraph “3.2/3.3 Burner and
nozzle characteristics table”).
4.
Replace the burners in the correct position.
The nozzles for using city gas (G110 – 8 mbar) are available from authorised service centres.