Instructions for the installer
35
2
INSTALLING THE APPLIANCE
The appliance must be installed by a qualified technician and according to the regulations in force.
Depending on the type of installation, it belongs to class 1 (Fig.A) or to class 2, subclass 1 (Fig.B-C).
This appliance may be installed next to walls, one of which must be higher than the appliance, at a
minimum distance of 50 mm from the side of the appliance, as shown in drawings A and B relative to
the installation classes. Any wall cupboards or ventilation hoods must be at a distance of at least 750
mm above the work surface.
A
B
Built-in
appliance
Free-standing
installation
A
B
Built-in
appliance
Free-standing
installation
C
Appliances equipped with a gas cylinder compartment and electric oven can only be
installed as free-standing (see fig.
B
).