5.5 Electrical connection
General information
Check the mains characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned on the appliance. Do not
remove this plate for any reason. Perform
the ground connection using a wire that is
20 mm longer than the other wires.
For New Zealand only:
If this cooking
range is to be connected to a new or
upgraded electrical installation, then it must
be connected to the supply by a supply
cord fitted with:
• an appropriately rated plug that is
compatible with the socket-outlet fitted to
the final sub-circuit in the fixed wiring that
supplies this cooking range; or
• an appropriately rated installation male
connector that is compatible with the
installation female connector fitted to tge
final sub-circuit in the fixed wiring that
supplies this cooking range.
The appliance can work in the following
modes:
•
220-240 V 1N
~
3 x 6 mm²
three-pole
cable.
•
380-415 V 2N
~
4 x 2.5 mm²
four-pole
cable.
•
380-415 V 3N
~
5 x 1.5 mm²
five-pole
cable.
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technicians.
• Use personal protective equipment.
• The appliance must be connected to
ground in compliance with electrical
system safety standards.
• Disconnect the mains power supply.
• Do not pull the cable to remove the
plug.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of
the terminal board leads must be
1.5 .- 2 Nm.
The values indicated above refer
to the cross-section of the internal
lead.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).