![Smeg A1PYID-9 Manual Download Page 32](http://html1.mh-extra.com/html/smeg/a1pyid-9/a1pyid-9_manual_1301403032.webp)
Installation
34
5 Installation
5.1 Minimum clearance to combustible surfaces
Freestanding cooker
A
600 mm (Overhead) measured from the
highest part of the highest burner and 750
mm for an exhaust fan.
B
200 mm (Vertical combustible surface)
measured form the edge of the nearest
burner.
C
10 mm (Horizontal combustible surface)
below the hob.
5.2 Gas connection
Carefully screw the connector
3
to the
appliance’s gas connector
1
(1/2” thread
ISO 228-1), placing the supplied seal
2
between them.
This appliance must be installed by an
authorised person in accordance with this
instruction manual, AS/NZS 5601.1 –
Gas installations (installation and pipe
sizing), local gas fitting regulations, local
electrical regulations, local health
regulations, Building Code of Australia and
any other government authority.
Refer to AS/NZS 5601
(Protection of a combustible
surface) if the above minimum
clearances cannot be achieved.
The appliance connection point
shall be accessible with the
appliance installed.
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and
15 Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.