background image

No.VQC4000V-OMX0001 

 

             
    

  Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They are  all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

 , and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218: Manipulating industrial robots -Safety.

                                         

 

 

  etc.

 

   

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

 

Since the product specified here is used under various operating conditions, its compatibility with specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This person should also continuously review all specifications of the product referring to its latest catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The assembly, operation and maintenance of machines or equipment including our products must be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

 

-2- 

Summary of Contents for VQC4000

Page 1: ...Doc No VQC4000V OMX0001 Solenoid Valve PRODUCT NAME VQC4000Series Pilot Valve V100 MODEL Series Product Number...

Page 2: ...ubrication 7 Air Supply 7 Operating Environment 8 Maintenance 8 Specific Product Precautions 9 10 Manifold option Assembly Part No 11 Construction 12 List of valves options and Mounting Bolts 13 Elect...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Page 4: ...failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Page 5: ...or other foreign matter from entering inside the valve In addition at the time of vacuum adsorption be sure to supply a constant supply of vacuum Failure to do so may result in foreign matter stickin...

Page 6: ...status by the breakage If the energizing continues in this status a large current flows This may cause secondary damage to the output circuit external peripheral device or valve and may also cause fi...

Page 7: ...nce activities When installing the products allow access for maintenance 3 Tighten threads with the proper tightening torque When installing the products follow the listed torque specifications 4 If a...

Page 8: ...non lube state This prevents accumulation of oil inside the pilot valve Air Supply 1 Type of fluids Please consult with SMC when using the product in applications other than compressed air 2 When ther...

Page 9: ...supply exhaust of compressed air Before components are removed first confirm that measures are in place to prevent workpieces from dropping run away equipment etc Then cut off the supply air and elect...

Page 10: ...h your finger until it stops and turn it clockwise 90 to lock it Turn it counterclockwise to release it Do not apply excessive torque when turning the manual override 0 1 N m or less Valve Mounting Af...

Page 11: ...l the cover hook locks without twisting the protective O ring When pushed in the hook opens and locks automatically Replacement of Pilot Valve Removal Remove the mounting screw that holds the pilot va...

Page 12: ...11 VQC4000V OMX0001 Manifold Options Manifold Assembly Part No...

Page 13: ...12 VQC4000V OMX0001 Construction...

Page 14: ...13 VQC4000V OMX0001 List of Valves Options and Mounting Bolts...

Page 15: ...14 VQC4000V OMX0001...

Page 16: ...15 VQC4000V OMX0001...

Page 17: ...16 VQC4000V OMX0001...

Page 18: ...17 VQC4000V OMX0001...

Page 19: ...18 VQC4000V OMX0001...

Page 20: ...enough to operate the valve take appropriate measures 2 Leakage current When the power turns off the valve can t be switched due to residual voltage Confirm the residual voltage is follows DC is 3 or...

Page 21: ...law 2 3 Tube is cut diagonally Check these items and replace part and re wire positively 2 4 Packing of one touch fitting is damaged Replace with one touch fitting 3 Air leaks through exhaust port R p...

Page 22: ...hiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manu...

Reviews: