background image

- 9 -

 

 

VQC4000V-OMX0001 

 

Continuous Duty 

 
 

When the product is continuously energized for a long 
period of time (10 minutes or longer), select the low 
wattage type (DC specification).   
 

Manual Override 

 

 

Since connected equipment will operate when the 
manual override is activated, confirm that 

 

conditions are safe prior to activation. 

 

 

Push type(Tool required) 

Push down the manual   
override button   
with a small screwdriver, etc.,   
until it stops. The manual override 
will return when released. 

 

 

Locking type (Tool required) 

Push down the manual 
override button with a small flat head screwdriver 
until it stops, and turn it clockwise 90° 
to lock it. Turn it counterclockwise 
to release it.   

 
 
 
 
 
 
 
 

 

Locking type (Manual) 

Push down the manual override button with a small flat 

head screwdriver or with your finger until it stops, and 
turn it clockwise 90° to lock it. Turn it counterclockwise 
to release it. 

 
 
 
 
 
 
 
 
 
 
Do not apply excessive torque when turning the manual 
override. [0.1 N·m or less] 
 
 
 
 
 
 
 
 
 

Valve Mounting 

 
 

After confirming that the gasket is installed correctly, 
securely tighten the mounting screws according to 
the tightening torque shown below. 

 
 
 
 
 
 
 
 
 

 

Replacement of One-touch Fittings 

 

 

Cylinder port fittings are available in cassette type 
and can be replaced easily. Fittings are secured with a 
retaining clip that is inserted from the top side of the 
valve. After removing the valve, remove the clip with a 
flat head screwdriver to replace the fittings. To mount 
a fitting, insert the fitting assembly until it stops and 
reinsert the retaining clip to its designated position. 
 
 
 
 
 
 
 
 
 
 
 
 

Lead Wire Connection

 

 
 

Plug-in sub-plate (With terminal block) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

VQC4000 Series 

Specific Product Precautions 1 

 

Be sure to read before handling. Refer to main text for detailed precautions on every series.   

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VQC4000

Page 1: ...Doc No VQC4000V OMX0001 Solenoid Valve PRODUCT NAME VQC4000Series Pilot Valve V100 MODEL Series Product Number...

Page 2: ...ubrication 7 Air Supply 7 Operating Environment 8 Maintenance 8 Specific Product Precautions 9 10 Manifold option Assembly Part No 11 Construction 12 List of valves options and Mounting Bolts 13 Elect...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Page 4: ...failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Page 5: ...or other foreign matter from entering inside the valve In addition at the time of vacuum adsorption be sure to supply a constant supply of vacuum Failure to do so may result in foreign matter stickin...

Page 6: ...status by the breakage If the energizing continues in this status a large current flows This may cause secondary damage to the output circuit external peripheral device or valve and may also cause fi...

Page 7: ...nce activities When installing the products allow access for maintenance 3 Tighten threads with the proper tightening torque When installing the products follow the listed torque specifications 4 If a...

Page 8: ...non lube state This prevents accumulation of oil inside the pilot valve Air Supply 1 Type of fluids Please consult with SMC when using the product in applications other than compressed air 2 When ther...

Page 9: ...supply exhaust of compressed air Before components are removed first confirm that measures are in place to prevent workpieces from dropping run away equipment etc Then cut off the supply air and elect...

Page 10: ...h your finger until it stops and turn it clockwise 90 to lock it Turn it counterclockwise to release it Do not apply excessive torque when turning the manual override 0 1 N m or less Valve Mounting Af...

Page 11: ...l the cover hook locks without twisting the protective O ring When pushed in the hook opens and locks automatically Replacement of Pilot Valve Removal Remove the mounting screw that holds the pilot va...

Page 12: ...11 VQC4000V OMX0001 Manifold Options Manifold Assembly Part No...

Page 13: ...12 VQC4000V OMX0001 Construction...

Page 14: ...13 VQC4000V OMX0001 List of Valves Options and Mounting Bolts...

Page 15: ...14 VQC4000V OMX0001...

Page 16: ...15 VQC4000V OMX0001...

Page 17: ...16 VQC4000V OMX0001...

Page 18: ...17 VQC4000V OMX0001...

Page 19: ...18 VQC4000V OMX0001...

Page 20: ...enough to operate the valve take appropriate measures 2 Leakage current When the power turns off the valve can t be switched due to residual voltage Confirm the residual voltage is follows DC is 3 or...

Page 21: ...law 2 3 Tube is cut diagonally Check these items and replace part and re wire positively 2 4 Packing of one touch fitting is damaged Replace with one touch fitting 3 Air leaks through exhaust port R p...

Page 22: ...hiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manu...

Reviews: