Page 1: ...Doc No VQC1000V OMM0002 B PRODUCT NAME Solenoid Valve MODEL Series VQC1000 2000 Series Pilot Valve V100...

Page 2: ...2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 7 Air Supply 7 Operating Environment 7 Maintenance 7 8 Specific Product Precautions 9 15 Valve construction 16...

Page 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...re of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from...

Page 5: ...sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Regarding vacuum switch valves and vacuum release valves If a non vacuum valve is installed in the middle of a piping sys...

Page 6: ...n internal pilot type valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to th...

Page 7: ...reference value for the tightening torque refer to the table below 2 The gasket can be reused up to 6 to 10 times It can be replaced easily when it has sustained damage A broken gasket can be removed...

Page 8: ...alve and cause it to malfunction For compressed air quality refer to the SMC Best Pneumatics No 6 catalog Operating Environment 1 Do not use in an atmosphere containing corrosive gases chemicals sea w...

Page 9: ...n the valve to confirm the operating condition and check for any air leakage 1 Drain flushing Remove drainage from the air filters regularly 2 Lubrication In the case of rubber seals once lubrication...

Page 10: ...ON side with a small flat head screwdriver or with your fingers Slide it to the fitting side OFF side to release it In addition it can also be used as a push type by using a screwdriver etc of 1 7 or...

Page 11: ...rings must be free from scratches and dust Otherwise air leakage may result 2 After screwing in the fittings mount the M5 fitting assembly on the manifold base Tightening torque 0 8 to 1 2 N m 3 Purc...

Page 12: ...ated in the end plate on both sides of the manifold base A dirty and choked element may reduce cylinder speed or cause malfunction Clean or replace the dirty element How to Calculate Flow Rate Convers...

Page 13: ...ide waterproof caps when there are unused ports and perform proper mounting of input units input blocks SI units and manifold valves Provide a cover or other protection for applications in which there...

Page 14: ...kely damage the product IP67 protection class cannot be guaranteed if the screws are not tightened to the specified torque 4 When lifting a large size manifold solenoid valve unit take care to avoid c...

Page 15: ...a surge generating load is directly driven the unit may be damaged 7 The product is CE marked but not immune to lightning strikes Take measures against lightning strikes in your system 8 Keep dust wir...

Page 16: ...units take care not to get fingers caught between units Injury can result 2 Perform periodic inspection Unexpected malfunction in the system composition devices is likely to occur due to malfunction o...

Page 17: ...16 No VQC1000V OMM0001 B...

Page 18: ...17 No VQC1000V OMM0001 B...

Page 19: ...18 No VQC1000V OMM0001 B...

Page 20: ...19 No VQC1000V OMM0001 B...

Page 21: ...20 No VQC1000V OMM0001 B...

Page 22: ...21 No VQC1000V OMM0001 B...

Page 23: ...22 No VQC1000V OMM0001 B...

Page 24: ...23 No VQC1000V OMM0001 B...

Page 25: ...24 No VQC1000V OMM0001 B...

Page 26: ...25 No VQC1000V OMM0001 B...

Page 27: ...26 No VQC1000V OMM0001 B...

Page 28: ...27 No VQC1000V OMM0001 B...

Page 29: ...28 No VQC1000V OMM0001 B...

Page 30: ...29 No VQC1000V OMM0001 B...

Page 31: ...30 No VQC1000V OMM0001 B...

Page 32: ...e measures 2 Leakage current When the power turns off the valve can t be switched due to residual voltage Confirm the residual voltage is follows DC is 3 or less of rated voltage 3 Failure of pilot va...

Page 33: ...these items and replace part and re wire positively 2 4 Packing of one touch fitting is damaged Replace with one touch fitting 3 Air leaks through exhaust port R port Note The valve with metal seal a...