- 4 -

 

No.VQC1000V-OMM0002-B 

Caution 

 

Design / Selection 

 

 

1. Confirm the specifications 

Products represented in this catalog are designed only for use in 
compressed air systems (including vacuum). 
Do  not  operate  at  pressures  or  temperatures,  etc.,  beyond  the 
range  of  specifications,  as  this  can  cause  damage  or 
malfunction.(Refer to the specifications.) 
Please contact SMC  when  using  a  fluid  other  than compressed 
air (including vacuum). 
We do not guarantee against any damage if the product is used 
outside of the specification range. 

2. Actuator drive 

 

When  an  actuator,  such  as  a  cylinder,  is  to  be  driven  using  a 
valve,  take  appropriate  measures  (such  as  the  installation  of  a 
cover  or  the  restricting  of  access  to  the  product)  to  prevent 
potential danger caused by actuator operation. 

3. Intermediate stops 

Rubber seal: Use a closed center type valve. 

Metal  seal:  For  the  exhaust  center  type  valve,  use  in 

combination with either a double check spacer or a double check 
block. 

For the 3-position closed center, it is difficult to make the piston 

stop at the required position accurately due to the compressibility 
of air. 

Furthermore,  since  valves  and  cylinders  are  not  guaranteed  for 

zero air leakage, it may not be possible to hold a stopped position 
for an extended period of time. 

However, as the metal seal closed center type valve leaks more 

air  than  the  rubber  seal,  the  intermediate  stopping  time  will  be 
shorter. 

4. Effect of back pressure when using a manifold. 

Use  caution  when  valves  are  used  on  a  manifold  because 
actuators may malfunction due to back pressure. 
Especially  when  using  a  3-position  exhaust  center  valve  or  a 
single  acting  cylinder,  take  appropriate  measures  to  prevent 
malfunction by using it with an individual EXH spacer assembly, a 
back pressure check valve, or an individual exhaust manifold. 

5. Holding pressure (including vacuum). 

Since the valve are subject to air leakage, they cannot be used 
for applications such as holding pressure (including vacuum) in a 
pressure vessel. 

6.  Not  suitable  for  use  as  an  emergency  shut-off 

valve, etc.

 

The valves listed in this instruction manual are not designed for 
safety  applications  such  as  an  emergency  shutoff  valve.  If  the 
valves are used for the mentioned applications, additional safety 
measures should be adopted. 

7. Release of residual pressure 

 

For  maintenance  and  inspection  purposes  install  a  system  for 
releasing  residual  pressure.  Especially  in  the  case  of  the 
3-position closed center valve, ensure that the residual pressure 
between the valve and the cylinder is released. 

8. Operation in a vacuum condition 

When a valve is used for switching a vacuum, take measures to 

install  a suction  filter  or similar  to prevent  external  dust  or  other 
foreign matter from entering inside the valve. 

In addition, at the time of vacuum adsorption, be sure to supply a 

constant supply of vacuum. Failure to do so may result in foreign 
matter sticking to the adsorption pad or air leakage, causing the 
workpiece to drop. 

 
 
 
 

9.

 

Regarding  vacuum  switch  valves  and  vacuum 

release valves 

  If a non-vacuum valve is installed in the middle of a piping system 

that contains a vacuum, the vacuum condition will not be 
maintained. Use a valve designed for use under vacuum conditions.

 

10. Double solenoid type 

    When  using  the  double solenoid  type  for  the  first time,  actuators 

may travel in an unexpected direction depending on the switching 
position of the valve. Implement measures to prevent any danger 
from occurring when operating the actuator.   

11. Ventilation 

    Provide ventilation when using a valve in a confined area, such as 

in  a  closed  control  panel.  For  example,  install  a  ventilation 
opening,  etc.  in  order  to  prevent pressure from  increasing inside 
of  the  confined  area  and  to  release  the  heat  generated  by  the 
valve. 

12.Extended periods of continuous energization 

If a valve will be continuously energized for an extended period 

of time, the temperature of the valve will increase due to the heat 
generated  by  the  coil  assembly.  This  will  likely  adversely  affect 
the  performance  of  the  valve  and  any  nearby  peripheral 
equipment. Therefore, if the valve is to be energized for periods 
of  longer  than  30  minutes  at  a  time  or  if  during  the  hours  of 
operation  the  energized  period  per  day  is  longer  than  the 
de-energized period, we advise using a valve with specifications 
listed below. 

A 0.4 W or lower valve, such as the SY series, or a valve with a 

power-saving circuit 

If  conflicting  instructions  are  given  in  the  “Specific  Product 
Precautions”  or  on  the  “How  to  Order  Valves”  page,  give  them 
priority. 

13.Do  not  disassemble  the  product  of  make  any 

modifications, including additional machining. 

  Doing so may cause human injury and/or an accident.. 

14.

 

Resumption after a long period of holding time 

When  resuming  operation  after  a  long  period  of  holding  time, 
there are cases in which, regardless of whether the product is in 
an ON or OFF state, there is a delay in the initial response time 
due  to  adhesion.  Conducting  several  cycles  of  running-in 
operation  will  solve  this  problem.  Please  consider  implementing 
this before resumption. 

 

 

1.  Precautions  for  2-position  double  solenoid 

valves 

If  a  double  solenoid  valve  is  operated  with  momentary 
energization, it should be energized for at least 0.1 seconds. 
However,  depending  on  the  piping  conditions,  the  cylinder  may 
malfunction even when the double solenoid valve is energized for 
0.1 seconds or longer. In this case, energize the double solenoid 
valve until the cylinder is exhausted completely.

 

2. Leakage voltage 

Take note that the leakage voltage will increase when a resistor is 
used  in  parallel  with  a  switching  element  or  when  a  C-R  circuit 
(surge  voltage  suppressor)  is  used  for  protecting  a  switching 
device  because  of  the  leakage  voltage  passing  through  the  C-R 
circuit.  The  suppressor  residual  leakage  voltage  should  be  as 
follows. 

 

 

 

 

 

DC coil

 

Should be 3% or less of the rated voltage. 

VQC1000/2000 Series 

Precautions  for  5  Port  Solenoid  Valve 

 

 

Be sure to read before handling.   

Warning 

Summary of Contents for VQC1000

Page 1: ...Doc No VQC1000V OMM0002 B PRODUCT NAME Solenoid Valve MODEL Series VQC1000 2000 Series Pilot Valve V100...

Page 2: ...2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 7 Air Supply 7 Operating Environment 7 Maintenance 7 8 Specific Product Precautions 9 15 Valve construction 16...

Page 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...re of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from...

Page 5: ...sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Regarding vacuum switch valves and vacuum release valves If a non vacuum valve is installed in the middle of a piping sys...

Page 6: ...n internal pilot type valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to th...

Page 7: ...reference value for the tightening torque refer to the table below 2 The gasket can be reused up to 6 to 10 times It can be replaced easily when it has sustained damage A broken gasket can be removed...

Page 8: ...alve and cause it to malfunction For compressed air quality refer to the SMC Best Pneumatics No 6 catalog Operating Environment 1 Do not use in an atmosphere containing corrosive gases chemicals sea w...

Page 9: ...n the valve to confirm the operating condition and check for any air leakage 1 Drain flushing Remove drainage from the air filters regularly 2 Lubrication In the case of rubber seals once lubrication...

Page 10: ...ON side with a small flat head screwdriver or with your fingers Slide it to the fitting side OFF side to release it In addition it can also be used as a push type by using a screwdriver etc of 1 7 or...

Page 11: ...rings must be free from scratches and dust Otherwise air leakage may result 2 After screwing in the fittings mount the M5 fitting assembly on the manifold base Tightening torque 0 8 to 1 2 N m 3 Purc...

Page 12: ...ated in the end plate on both sides of the manifold base A dirty and choked element may reduce cylinder speed or cause malfunction Clean or replace the dirty element How to Calculate Flow Rate Convers...

Page 13: ...ide waterproof caps when there are unused ports and perform proper mounting of input units input blocks SI units and manifold valves Provide a cover or other protection for applications in which there...

Page 14: ...kely damage the product IP67 protection class cannot be guaranteed if the screws are not tightened to the specified torque 4 When lifting a large size manifold solenoid valve unit take care to avoid c...

Page 15: ...a surge generating load is directly driven the unit may be damaged 7 The product is CE marked but not immune to lightning strikes Take measures against lightning strikes in your system 8 Keep dust wir...

Page 16: ...units take care not to get fingers caught between units Injury can result 2 Perform periodic inspection Unexpected malfunction in the system composition devices is likely to occur due to malfunction o...

Page 17: ...16 No VQC1000V OMM0001 B...

Page 18: ...17 No VQC1000V OMM0001 B...

Page 19: ...18 No VQC1000V OMM0001 B...

Page 20: ...19 No VQC1000V OMM0001 B...

Page 21: ...20 No VQC1000V OMM0001 B...

Page 22: ...21 No VQC1000V OMM0001 B...

Page 23: ...22 No VQC1000V OMM0001 B...

Page 24: ...23 No VQC1000V OMM0001 B...

Page 25: ...24 No VQC1000V OMM0001 B...

Page 26: ...25 No VQC1000V OMM0001 B...

Page 27: ...26 No VQC1000V OMM0001 B...

Page 28: ...27 No VQC1000V OMM0001 B...

Page 29: ...28 No VQC1000V OMM0001 B...

Page 30: ...29 No VQC1000V OMM0001 B...