Operating Environment 

 
 

1. Do not use in an atmosphere containing an inflammable 

gas or explosive gas. 

Use in such an atmosphere is likely to cause a fire or explosion. 
This system is not explosion-proof. 
 
 

1. Select the proper type of enclosure according to the 

environment of operation. 

IP65/67 protection class is achieved when the following 
conditions are met. 
1) The units are connected properly with wiring cable for power 

supply, communication connector, and cable with M12 
connector. 

2) Suitable mounting of each unit and manifold valve. 
3) Be sure to mount a seal cap on any unused connectors. 

If using in an environment that is exposed to water splashes, 
please take measures such as using a cover. 

When EX600-D

E or EX600-D

F are connected, the 

enclosure of the manifold should be IP40. 
Also, the Handheld Terminal confirms to IP20, so prevent 
foreign matter from entering inside, and water, solvent or oil from 
coming in direct contact with it. 

2. Provide adequate protection when operating in locations 

such as the following. 

Failure to do so may cause damage or malfunction. The effect 
of countermeasures should be checked in individual equipment 
and machine. 
1) Where noise is generated by static electricity, etc. 
2) Where there is a strong electric field 
3) Where there is a danger of exposure to radiation 
4) When in close proximity to power supply lines 

3. Do not use in an environment where oil and chemicals are 

used. 

Operating in environments with coolants, cleaning solvents, 
various oils or chemicals may cause adverse effects (damage, 
malfunction) to the unit even in a short period of time. 

4. Do not use in an environment where the product could be 

exposed to corrosive gas or liquid. 

This may damage the unit and cause it to malfunction. 

5. Do not use in locations with sources of surge generation. 

Installation of the unit in an area around the equipment 
(electromagnetic lifters, high frequency induction furnaces, 
welding machine, motors etc.), which generates the large surge 
voltage could cause to deteriorate an internal circuitry element 
of the unit or result in damage. Implement countermeasures 
against the surge from the generating source, and avoid 
touching the lines with each other. 

6. Use the product type that has an integrated surge 

absorption element when directly driving a load which 
generates surge voltage by relay, solenoid valves or lamp. 

When a surge generating load is directly driven, the unit may be 
damaged. 

7. The product is CE marked, but not immune to lightning 

strikes. Take measures against lightning strikes in your 
system. 

8. Keep dust, wire scraps and other extraneous material from 

getting inside the product. 

This may cause malfunction or damage. 

9. Mount the unit in such locations, where no vibration or 

shock is affected. 

This may cause malfunction or damage. 

10. Do not use in places where there are cyclic temperature 

changes. 

In case that the cyclic temperature is beyond normal 
temperature changes, the internal unit is likely to be adversely 
effected. 
 

 
 

11. Do not use in direct sunlight. 

Do not use in direct sunlight. It may cause malfunction or 
damage. 

12. Use this product within the specified ambient temperature 

range. 

This may cause malfunction. 

13. Do not use in places where there is radiated heat around 

it. 

Such a place is likely to cause malfunction. 
 

Adjustment/Operation 

 
 

1. Do not perform operation or setting with wet hands. 

There is a risk of electrical shock. 

<Handheld Terminal> 
2. Do not apply pressure to the LCD display. 

There is a possibility of the crack of LCD display and injuring. 

3. The forced input/output function is used to change the 

signal status forcibly. When operating this function, be 
sure to check the safety of the surroundings and 
installation. 

Otherwise, injury or equipment damage could result. 

4. Incorrect setting of parameters can cause malfunction. Be 

sure to check the settings before use. 

This may cause injury or equipment damage. 
 
 

1. 

Use a watchmaker’s screwdriver with thin blade for the 
setting of each switch of the SI unit.   
When setting the switch, do not touch other unrelated 
parts. 

This may cause parts damage or malfunction due to a short 
circuit. 

2. Provide adequate setting for the operating conditions. 

Failure to do so could result in malfunction.   
Refer to the instruction manual for setting of the switches. 

3. For the details of programming and address setting, refer 

to the manual from the PLC manufacturer. 

The content of programming related to protocol is designed by 
the manufacturer of the PLC used. 

<Handheld Terminal> 
4. Do not press the setting buttons with a sharp pointed 

object. 

This may cause damage or malfunction. 

5. Do not apply excessive load and impact to the setting 

buttons. 

This may cause damage, equipment failure or malfunction. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Trademark 

DeviceNet™ is a trademark of ODVA. 
Product  names  described  in  this  catalog  may  be  used  as  trademarks  by 
each manufacturer.

 

 

VQC1000/2000 series 

Specific Product Precautions 6 

  Be sure to read this before handling 

 

 

 

 

EX600 Precautions

 

 

Summary of Contents for VQC1000

Page 1: ...Doc No VQC1000V OMM0002 B PRODUCT NAME Solenoid Valve MODEL Series VQC1000 2000 Series Pilot Valve V100...

Page 2: ...2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 7 Air Supply 7 Operating Environment 7 Maintenance 7 8 Specific Product Precautions 9 15 Valve construction 16...

Page 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...re of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from...

Page 5: ...sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Regarding vacuum switch valves and vacuum release valves If a non vacuum valve is installed in the middle of a piping sys...

Page 6: ...n internal pilot type valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to th...

Page 7: ...reference value for the tightening torque refer to the table below 2 The gasket can be reused up to 6 to 10 times It can be replaced easily when it has sustained damage A broken gasket can be removed...

Page 8: ...alve and cause it to malfunction For compressed air quality refer to the SMC Best Pneumatics No 6 catalog Operating Environment 1 Do not use in an atmosphere containing corrosive gases chemicals sea w...

Page 9: ...n the valve to confirm the operating condition and check for any air leakage 1 Drain flushing Remove drainage from the air filters regularly 2 Lubrication In the case of rubber seals once lubrication...

Page 10: ...ON side with a small flat head screwdriver or with your fingers Slide it to the fitting side OFF side to release it In addition it can also be used as a push type by using a screwdriver etc of 1 7 or...

Page 11: ...rings must be free from scratches and dust Otherwise air leakage may result 2 After screwing in the fittings mount the M5 fitting assembly on the manifold base Tightening torque 0 8 to 1 2 N m 3 Purc...

Page 12: ...ated in the end plate on both sides of the manifold base A dirty and choked element may reduce cylinder speed or cause malfunction Clean or replace the dirty element How to Calculate Flow Rate Convers...

Page 13: ...ide waterproof caps when there are unused ports and perform proper mounting of input units input blocks SI units and manifold valves Provide a cover or other protection for applications in which there...

Page 14: ...kely damage the product IP67 protection class cannot be guaranteed if the screws are not tightened to the specified torque 4 When lifting a large size manifold solenoid valve unit take care to avoid c...

Page 15: ...a surge generating load is directly driven the unit may be damaged 7 The product is CE marked but not immune to lightning strikes Take measures against lightning strikes in your system 8 Keep dust wir...

Page 16: ...units take care not to get fingers caught between units Injury can result 2 Perform periodic inspection Unexpected malfunction in the system composition devices is likely to occur due to malfunction o...

Page 17: ...16 No VQC1000V OMM0001 B...

Page 18: ...17 No VQC1000V OMM0001 B...

Page 19: ...18 No VQC1000V OMM0001 B...

Page 20: ...19 No VQC1000V OMM0001 B...

Page 21: ...20 No VQC1000V OMM0001 B...

Page 22: ...21 No VQC1000V OMM0001 B...

Page 23: ...22 No VQC1000V OMM0001 B...

Page 24: ...23 No VQC1000V OMM0001 B...

Page 25: ...24 No VQC1000V OMM0001 B...

Page 26: ...25 No VQC1000V OMM0001 B...

Page 27: ...26 No VQC1000V OMM0001 B...

Page 28: ...27 No VQC1000V OMM0001 B...

Page 29: ...28 No VQC1000V OMM0001 B...

Page 30: ...29 No VQC1000V OMM0001 B...

Page 31: ...30 No VQC1000V OMM0001 B...

Page 32: ...e measures 2 Leakage current When the power turns off the valve can t be switched due to residual voltage Confirm the residual voltage is follows DC is 3 or less of rated voltage 3 Failure of pilot va...

Page 33: ...these items and replace part and re wire positively 2 4 Packing of one touch fitting is damaged Replace with one touch fitting 3 Air leaks through exhaust port R port Note The valve with metal seal a...

Page 34: ...truction Manifold Options 2020 7 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prio...

Reviews: