Valve for Water and Chemical Base Fluids
VCC
Series
L1
L2
2
n
L1 = n / 2 x 30 + 16 L2 = n / 2 x 30 + 32
∗
n = Number of valves (cleaning valve + gate valve + other valves)
< >: Pilot port is C6.
n: Stations (mm)
46
62
4
76
92
6
106
122
8
136
152
10
166
182
12
196
212
14
226
242
16
256
272
18
286
302
20
316
332
22
346
362
24
376
392
26
406
422
28
436
452
30
466
482
32
496
512
34
526
542
36
556
572
38
586
602
40
616
632
n
6
4
2
3
n-1
5
3
1
1
2
VV2CC1
VVMCC1, VV3CC1
n-1
9
7
5
3
1
0.5 to 2
0.5 to 2
0.5 to 2
0.5 to 2
122.2 <124.2>
142.2 <144.2>
10
10
75
25
80
22.6
L2
L1
8
30
31
100
120
3 port valve
2 port valve
Pilot port
C4: ø4 One-touch fitting
C6: ø6 One-touch fitting
G1/4 (RETURN port)
G1/4 (IN port)
4 x ø9
(for M8
mounting)
n
10
8
6
4
2
Manifold
Dimensions
50
142.2 <144.2>
120
20
67.5 <69.5>
64.9
G1/4
OUT port
122.2 <124.2>
100
67.5 <69.5>
50
20
G1/4
OUT port
64.9
10.5
8
50
Leakage detection port
0.5 to 2
0.5 to 2
0.5 to 2
0.5 to 2
122.2 <124.2>
142.2 <144.2>
10
10
75
25
80
22.6
L2
L1
8
30
31
100
120
2 port valve
3 port valve
Cleaning valve +
Gate valve
Pilot port
C4: ø4 One-touch fitting
C6: ø6 One-touch fitting
G1/4 (RETURN port)
G1/4 (IN port)
4 x ø9
(for M8
mounting)
Gate valve
∗
Aluminum + hard anodized containing PTFE and
POM are used for a part of the manifold material.
Refer to page 660 for details.
13
2021-06-10 14:35