background image

SMC Smoke Detector Guide 

 

 Copyright 

©

2011 SMC Networks

  

Page 10 

 

All Rights Reserved 

 

I/M SMCSMXX-Z rev. 2.0 

7/26/11 

If this equipment does cause harmful interference to 
radio or television reception, which can be 
determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference 
by one of the following measures: 

¾

 

Reorient or relocate the receiving antenna. 

¾

 

Increase the separation between the equipment 
and receiver. 

¾

 

Connect the equipment into an outlet on a circuit 
different from that to which the receiver is 
connected. 

Consult the dealer or an experienced radio/TV 
technician for help. 

FCC Caution: Any changes or modifications not 
expressly approved by the party responsible for 
compliance could void the user's authority to operate 
this equipment. 

This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, 
and (2) this device must accept any interference 
received, including interference that may cause 
undesired operation. 

Industry Canada Statement 

This device complies with RSS-210 of the Industry 
Canada Rules. Operation is subject to the following 
two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any 
interference received, including interference that 
may cause undesired operation. 

Ce dispositif est conforme à la norme CNR-210 
d'Industrie Canada applicable aux appareils radio 
exempts de licence. Son fonctionnement est sujet aux 

deux conditions suivantes: (1) le dispositif ne doit pas 
produire de brouillage préjudiciable, et (2) ce 
dispositif doit accepter tout brouillage reçu, y 
compris un brouillage susceptible de provoquer un 
fonctionnement indésirable. 

IMPORTANT NOTE: 
Radiation Exposure Statement: 

The product complies with the US/Canada portable 
RF exposure limit set forth for an uncontrolled 
environment and are safe for intended operation as 
described in this manual. The further RF exposure 
reduction can be achieved if the product can be kept 
as far as possible from the user body or set the device 
to lower output power if such function is available. 

NOTE IMPORTANTE: (Pour l'utilisation des appareils 
portables) : 
Déclaration d'exposition aux radiations: 

Le produit est conforme aux limites d'exposition pour 
les appareils portables RF pour les Etats-Unis et le 
Canada établies pour un environnement non contrôlé. 

Le produit est sûr pour un fonctionnement tel que 
décrit dans ce manuel. La réduction aux expositions 
RF peut être augmentée si l'appareil peut être 
conservé aussi loin que possible du corps de 
l'utilisateur ou que le dispositif est réglé sur la 
puissance de sortie la plus faible si une telle fonction 
est disponible. 

This transmitter module is authorized only for use in 
devices where the antenna may be installed such that 
20 cm may be maintained between the antenna and 

users. 

Ce module émetteur est autorisé uniquement 
pour une utilisation dans un dispositif où 

l'antenne peut être installée de telle sorte 
qu'une distance de 20cm peut être maintenue 

entre l'antenne et les utilisateurs. 

Summary of Contents for SMCSM01-Z

Page 1: ...ed in all common areas and work spaces such as corridors lobbies storage rooms equipment rooms and other tenantless spaces in those environments suitable for proper detector operation in accordance with this code NFPA 72 2 1 4 2 3 Selective Coverage Where codes standards laws or authorities having jurisdiction require the protection of selected areas only the specified areas shall be protected in ...

Page 2: ... to protect and their burning characteristics Human occupancy Total area to be monitored Ceiling height and surface condition Air movement and vent locations Obstructions Deflections After considering these factors choose a location Where the temperature range is between 40 and 100 F 4 4 and 37 8 C Where the humidity is between 0 and 90 noncondensing Away from ventilation sources that can prevent ...

Page 3: ... icon appears for that sensor E Fault each found sensor to pair it to the TouchScreen The icon for each sensor is undarkened as it is faulted and the TouchScreen beeps The sensor is paired to the TouchScreen F When all the sensors are found and paired tap Stop Any located sensors that were not paired are released by the TouchScreen a can be added later The Wireless Sens nd ors M ew its details Cha...

Page 4: ...led D Test communications between the control panel and smoke detector again Press the Test button on the alarm for 8 to 10 seconds The smoke detector sends a signal to the control panel Verify that the signal at the control panel was received E Test the smoke detector see section 9 F The control panel alarm and all auxiliary functions should be verified for a complete test of the system 9 Testing...

Page 5: ... security zones appear tap the zone you want to test for connectivity and follow the instructions from the TouchScreen After adding the smoke detector to the TouchScreen and installing the smoke detector test the signal strength between the TouchScreen and its added sensors security zones A Be sure steps A through D in section 6 Adding to the TouchScreen on page 3 have been performed Signal Streng...

Page 6: ...t or use a soft bristled brush to remove dust and dirt from the smoke chamber base G Line up the new smoke chamber with the optical base by aligning the arrows on the smoke chamber to the latches on the optical base and snap down into place H Replace the detector cap by lining up the cap with the smoke detector Then insert the cap into the smoke detector and turn clockwise approximately 15 degrees...

Page 7: ...B Tap the Turn Zone Off button for the smoke detector The Turn Zone Off button changes to Turn Zone On C When the system is disarmed the Security Status header shows that some zones have been bypassed 12 Delete the Smoke Detector Deleting a sensor such as your SMC Smoke Detector from the premises removes it from being monitored by the customer s system This is not the same as disabling bypassing a...

Page 8: ...ase the tamper switch The LED blinks green F Replace the front cover G Replace all the batteries to the smoke detector and the back cover 14 Compliance Statements Model SMCSM01 Z FCC ID JI5 SMCZB01 IC ID 4137A SMCZB01Z Model SMCSM02 Z FCC ID RU4 HWM6505 ZZ IC ID 9682A HWM6505 ZZ Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limi...

Page 9: ...areils radio exempts de licence Son fonctionnement est sujet aux deux conditions suivantes 1 le dispositif ne doit pas produire de brouillage préjudiciable et 2 ce dispositif doit accepter tout brouillage reçu y compris un brouillage susceptible de provoquer un fonctionnement indésirable IMPORTANT NOTE Radiation Exposure Statement The product complies with the US Canada portable RF exposure limit ...

Reviews: