7/26/11 

To attach the smoke detector to the mounting 
base:  

A. 

Line up the raised alignment tab on the lip 
of the smoke detector with the arrow on the 

mounting base. 

B. 

Insert the smoke detector into the base and 
turn clockwise approximately 15 degrees. It 

snaps firmly into place when secure.  

 

10   

View Zone Event History 

To view event history: 

A. 

Tap the Security widget on the Home 
screen. 

B. 

Tap the History tab. The Zone Event History 
shows the event history. 

 

11   

Disable Zones 

The system can bypass a zone, so the zone is not 

monitored when the system is armed. This is 
useful when a sensor (such as your SMC Smoke 

Detector) is being repaired. You can only change 
the Bypass state of a zone when the system is 

disarmed.  

The system continues to log the activity of 

bypassed zones in the Event History (see “View 
Zone Event History,” above). 

To bypass a zone: 

A. 

With the system disarmed, tap the Security 
app on the Home screen. 

B. 

Tap the Turn Zone Off button for the smoke 
detector. The Turn Zone Off button changes 
to Turn Zone On

C. 

When the system is disarmed, the Security 
Status header shows that some zones have 
been bypassed. 

 

12   

Delete the Smoke Detector 

Deleting a sensor (such as your SMC Smoke 
Detector) from the premises removes it from 

being monitored by the customer’s system. 
This is not the same as disabling (bypassing) a 

sensor. You should delete a sensor only: 

¾

 

If the sensor is being removed from the 

premises  

¾

 

To reset the sensor to factory default 

settings by deleting the sensor and re-adding 
it immediately. 

To delete a sensor from the system:  

A. 

Contact Customer Care to obtain the 
Premise Passphrase for the current customer 

account.

 

B. 

Perform steps A through D in step 7, “Adding 
to the TouchScreen.”

 

C. 

When the Technician Settings menu appears, 
select Sensors & Zones > Delete a 

Sensor/Zone. The Premise Passphrase 
keyboard appears. 
Enter the Premise Passphrase an

D. 

d click 

Done. The currently installed 
sensors/security zones appear. 
Tap the zone you want to delete and fol
the instructions provided by the 

E. 

low 

TouchScreen to delete the sensor and 

security zone from the current system. 

 

 
Congratulations! You have successfully 

installed the SMC Smoke Detector. 

 

Summary of Contents for SMCSM01-Z

Page 1: ...ed in all common areas and work spaces such as corridors lobbies storage rooms equipment rooms and other tenantless spaces in those environments suitable for proper detector operation in accordance with this code NFPA 72 2 1 4 2 3 Selective Coverage Where codes standards laws or authorities having jurisdiction require the protection of selected areas only the specified areas shall be protected in ...

Page 2: ... to protect and their burning characteristics Human occupancy Total area to be monitored Ceiling height and surface condition Air movement and vent locations Obstructions Deflections After considering these factors choose a location Where the temperature range is between 40 and 100 F 4 4 and 37 8 C Where the humidity is between 0 and 90 noncondensing Away from ventilation sources that can prevent ...

Page 3: ... icon appears for that sensor E Fault each found sensor to pair it to the TouchScreen The icon for each sensor is undarkened as it is faulted and the TouchScreen beeps The sensor is paired to the TouchScreen F When all the sensors are found and paired tap Stop Any located sensors that were not paired are released by the TouchScreen a can be added later The Wireless Sens nd ors M ew its details Cha...

Page 4: ...led D Test communications between the control panel and smoke detector again Press the Test button on the alarm for 8 to 10 seconds The smoke detector sends a signal to the control panel Verify that the signal at the control panel was received E Test the smoke detector see section 9 F The control panel alarm and all auxiliary functions should be verified for a complete test of the system 9 Testing...

Page 5: ... security zones appear tap the zone you want to test for connectivity and follow the instructions from the TouchScreen After adding the smoke detector to the TouchScreen and installing the smoke detector test the signal strength between the TouchScreen and its added sensors security zones A Be sure steps A through D in section 6 Adding to the TouchScreen on page 3 have been performed Signal Streng...

Page 6: ...t or use a soft bristled brush to remove dust and dirt from the smoke chamber base G Line up the new smoke chamber with the optical base by aligning the arrows on the smoke chamber to the latches on the optical base and snap down into place H Replace the detector cap by lining up the cap with the smoke detector Then insert the cap into the smoke detector and turn clockwise approximately 15 degrees...

Page 7: ...B Tap the Turn Zone Off button for the smoke detector The Turn Zone Off button changes to Turn Zone On C When the system is disarmed the Security Status header shows that some zones have been bypassed 12 Delete the Smoke Detector Deleting a sensor such as your SMC Smoke Detector from the premises removes it from being monitored by the customer s system This is not the same as disabling bypassing a...

Page 8: ...ase the tamper switch The LED blinks green F Replace the front cover G Replace all the batteries to the smoke detector and the back cover 14 Compliance Statements Model SMCSM01 Z FCC ID JI5 SMCZB01 IC ID 4137A SMCZB01Z Model SMCSM02 Z FCC ID RU4 HWM6505 ZZ IC ID 9682A HWM6505 ZZ Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limi...

Page 9: ...areils radio exempts de licence Son fonctionnement est sujet aux deux conditions suivantes 1 le dispositif ne doit pas produire de brouillage préjudiciable et 2 ce dispositif doit accepter tout brouillage reçu y compris un brouillage susceptible de provoquer un fonctionnement indésirable IMPORTANT NOTE Radiation Exposure Statement The product complies with the US Canada portable RF exposure limit ...

Reviews: