3
CONFIGURATION COMMANDS
If the SMC configuration software is preferred not to be used the following commands can be used to
setup the instrument instead using the serial command prompt over both RS232 and RS485
All commands lines should be followed by a [CR] [LF]
Commands format
Description
$upiset,1
Sensor output rate in seconds
where “1” is
0.25s to 600s
$btrset,9600
The bitrate of the output. Accepted output rates are
4800, 9600, 19200, 38400, 57600 bps
$parset,n
Sets the parity of the serial output where
n = none
o = odd
e = even
$avgset,0
Sets the average time of the temperature and humidity
output. Can be set to 0 to 600s as integer values
$prtset,2
Output string format where
2 = WIXDR string format
3 = Vaisala HMP155 format
$un1set,1
Sets the unit for the temperature output
1 = Celsius
2 = Kelvin
3 = Fahrenheit
$cldget
To receive the sensor factory calibration date
$op1set,1.00
Sets the offset for the temperature sensor
$op2set,1.00
Sets the offset for the humidity sensor
$xdrset,SMC
Sets the name of the transducer in the WIXDR string
3.1
REPLIES FROM THE SMC-520
The sensor will reply with a confirmation when the command is accepted in the format as
$upians,1
where the three first letters are identical to the command and the three last letters in the identifier
are replaced with “ans”.
In case the command is not accepted the sensor will reply with
$ans cmd error
. In case of a problem
to store the information to the built-in flash memory of the sensor the device will reply with
$ans
mem err
. If a parameter is set outside the available range the sensor will return the message
$ans
range err
.