background image

- 9 - 

3-2. Piping 

 

   

Caution 

 

(1) Preparation before piping. 

Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove   
cutting chips, cutting oil and other debris from inside the pipe. 

 

(2) Wrapping of sealant tape. 

When connecting pipes and fittings, etc., be certain that cutting chips from the pipe threads and sealing   
material do not get inside the piping. Also, when sealant tape is used, leave 1 thread ridge exposed at end 
of the pipe / fitting. 

 
 
 
 
 
 
 
 
 
 
 

 

Figure-3 

3-3. Operating conditions 

 

   

Warning 

 

(1) Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water,   

steam, or where there is direct contact with any of these. 

 

(2) Do not expose the product to direct sunlight for an extended period of time. 

 

(3) Do not use in a place subject to heavy vibration and/or shock. 

 

(4) Do not mount the product in locations where it is exposed to radiant heat. 

 

(5) Do not use in dusty locations or where water or oil, etc., splash on the equipment. 

   

 

3-4. Cautions for mounting 

 

   

Warning

 

 

 

  

(1) Ensure sufficient space for maintenance work. 

   

When installing the product, allow access for maintenance. 

 

  

(2) Tighten threads to the proper tightening torque. 

   

When installing the product, follow the specified torque. 

 

  

(3) Do not perform additional machining to the product. 

Additional machining to the product can result in insufficient strength and cause damage to the product. 
This can lead to possible human injury and damage to the surrounding equipment. 

 

  

(4) Do not enlarge the fixed throttle by modifying the pipe connectors. 

   

If the hole diameter is enlarged, the product’s  piston  speed will increase, causing the shock force to 
increase and damage to the product. As a result, it could pose a hazard to humans and damage  the 
machinery and equipment.   

 
 
 

 

 

Sealant tape 

Expose approx. 1 thread 

Summary of Contents for RS2H Series

Page 1: ...Doc no RS2H OM0012P B PRODUCT NAME HEAVY DUTY STOPPER CYLINDER MODEL Series Product Number RS2H Series 50 to 80...

Page 2: ...rber resistance adjustment method 4 Operation P 12 5 Pneumatic circuit P 12 6 Maintenance P 13 6 1 Check items 6 2 How to replace shock absorber 6 3 Seal replacement 6 3 1 Disassembly Reassembly 6 3 2...

Page 3: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 4: ...replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior...

Page 5: ...e Standard stroke 50 30 63 30 80 40 1 4 Cylinder mass Action Bore size mm Mass kg Double acting Single acting spring retraction Double acting with spring 50 1 70 63 2 78 80 4 96 Bore size mm 50 63 80...

Page 6: ...lateral load F at operating pressure P For relationship between lateral load F and operating pressure P refer to Figure 2 1 P7 FA F YES Determine final model Figure 1 Impact of transferred object Mod...

Page 7: ...Operating range Lower limit Lower limit Upper limit Upper limit Mass of transferred object m kg Mass of transferred object m kg Transfer speed v m min Transfer speed v m min Coefficient of friction 0...

Page 8: ...ll parts remain secure 6 Consider a possible loss of power source Measures should be taken to protect against human injury and equipment damage in the event that there is a loss of power to equipment...

Page 9: ...bowl will overflow and allow the condensation to enter the compressed air lines This may cause malfunction of pneumatic equipment If the drain bowl is difficult to check and remove installation of a...

Page 10: ...and or shock 4 Do not mount the product in locations where it is exposed to radiant heat 5 Do not use in dusty locations or where water or oil etc splash on the equipment 3 4 Cautions for mounting Wa...

Page 11: ...e very careful when handling the product Depending on the handling method there is a risk that the corners of the product will injure your hand or fingers etc 3 5 How to change the relationship betwee...

Page 12: ...o secure the shock absorber dial Set screw M4 tightening torque 1 5N m Figure 6 Warning 1 Do not put your hand or finger between the lever holder and rod cover Do not put your hand or finger between t...

Page 13: ...k the condition of this and apply grease as necessary 4 Do not let your hand become caught when operating the cylinder The lever holder goes up and down while the cylinder is in operation Take care no...

Page 14: ...drive speed gradually increasing from a low speed to the desired speed setting 6 Maintenance 6 1 Check items The following checks are required for proper cylinder operation 1 Smoothness of performanc...

Page 15: ...firming that appropriate measures are in place to prevent sudden movement of cylinders 6 2 How to replace shock absorber Loosen the shock absorber set screw M4 on the stopper incline the lever by 90 a...

Page 16: ...exagon socket head cap screws with a hexagon wrench Detach the rod cover and piston rod from the cylinder tube When reassembling apply thread locker to the hexagon socket head cap screws and tighten H...

Page 17: ...y to prevent the gasket from coming off 3 O Ring Apply grease thinly to prevent the gasket from coming off 4 Cylinder components Apply grease to each part of the cylinder Figure 14 Figure 14 6 3 4 Sea...

Page 18: ...n a box Avoid direct sunlight and store seals at a low temperature and humidity Take special care to isolate and shield them from equipment which generates heat radiation and ozone Do not pile up a la...

Page 19: ...9 0 23 5 11 0 23 5 7 0 19 5 10 5 13 0 63 25 5 12 5 25 5 14 5 25 5 10 5 21 5 14 0 16 5 80 39 5 19 5 39 5 21 5 39 5 17 5 35 5 21 0 23 5 The values in brackets are for D A96 Auto switch Auto switch Auto...

Page 20: ...socket head cap screw M2 5X9 5L 1 to 2 turns Insert the temporarily tightened mounting bracket into the mating groove of the cylinder tube and slide the auto switch onto the cylinder tube through the...

Page 21: ...ard IP67 Immersion proof shape and oil proof shape by JEM standard IP67G Note 1 At load current 100 mA and cord length of 2 m Note 2 Between case and whole charging part 8 2 How to mount proximity swi...

Page 22: ...cylinder to almost zero which may lower sealing ability and result in malfunction 2 Defective equipment other than cylinder Examine all the equipment used in the system one by one Cylinder stops opera...

Page 23: ...ce cylinder away from it or shield it If cylinder is getting hot modify operating conditions such as frequency to keep the temperature below 60 C Replace cylinder if switch still does not turn on with...

Page 24: ...23...

Page 25: ...ion P 17 23 Wrapping of sealant tape is changed P 9 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to...

Reviews: