-47-
No.PF
※※
-OMW0004-A
Flow specification of the specified order (Flow unit: gal)
Model
PF3W704
PF3W720
PF3W740
Rated flow range
0.13 to 1.06 gal/min
0.53 to 4.23 gal/min
1.3 to 10.6 gal/min
In
s
ta
n
ta
n
e
o
u
s
fl
o
w
Display flow range
0.09 to 1.45 gal/min
(Flow under 0.09 L/min is
displayed as "0.00
“.)
0.45 to 5.81 gal/min
(Flow under 0.45 L/min is
displayed as "0.00“.)
0.9 to 14.5 gal/min
(Flow under 0.9 L/min is
displayed as "
0.0“.)
Setting flow range
0.09 to 1.45 gal/min
0.45 to 5.81 gal/min
0.9 to 14.5 gal/min
Min. setting/
display unit
0.01 gal/min
0.1 gal/min
Ac
c
u
m
u
la
te
d
fl
o
w
Setting/
display flow unit
99999999.9 gal
999999999 gal
Min. setting/
diplay unit
0.1 gal
1 gal
Conversion of
accumulated pulse
0.01 gal/pulse
0.05 gal/pulse
0.1 gal/pulse
Temperature specification of the specified order (Temperature unit:
o
F)
Rated temp. range
32 to 212
o
F
Setting/display temp. range
14 to 230
o
F
Min. setting/display unit
1
o
F
: The rated temperature range is only for the temperature sensor. As a whole product, the fluid temperature range is specified as 0 to 90
o
C.
Body specification (Flow unit: G)
Model
PF3W704
PF3W720
PF3W740
Rated flow range
0.13 to 1.06 gal/min
0.53 to 4.23 gal/min
1.3 to 10.6 gal/min
Display flow range
0.09 to 1.45 gal/min
(Flow under 0.09 L/min is
displayed as "0.00".)
0.45 to 5.81 gal/min
(Flow under 0.45 L/min is
displayed as "0.00".)
0.9 to 14.5 gal/min
(Flow under 0.9 L/min is
displayed as "0.00".)
Setting flow range
0.09 to 1.06 gal/min
0.45 to 5.81 gal/min
0.9 to 14.5 gal/min
Min. setting unit
0.01 L/min
0.1 L/min
Accumulated flow range
99,999,999.99 gal
999,999,999.9 gal
By 0.01 gal
By 0.1 gal
Conversion of
accumulated pulse
0.01 gal/pulse
0.05 gal/pulse
0.1 gal/pulse
Summary of Contents for PF3W504
Page 12: ...11 No PF OMW0004 A Model Indication and How to Order Integrated type Basic type...
Page 13: ...12 No PF OMW0004 A Integrated type Straight type...
Page 14: ...13 No PF OMW0004 A Remote type Supply type...
Page 15: ...14 No PF OMW0004 A Remote type Return type...
Page 55: ...54 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 56: ...55 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...
Page 58: ...57 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 59: ...58 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...