-41-
No.PF
※※
-OMW0004-A
Specifications
Manifold common specifications
Model
PF3WB
PF3WC
PF3WS
PF3WR
Manifold specifications
Integrated type
Remote type
Arrangement
1 to 10 station
1
Supply: 1 to 5 station
Return: 1 to 5 station
1 to 10 station
1
1 to 10 station
1
U
nit
Rated flow range
0.5 to 4 L/min, 2 to 16 L/min, 5 to 40 L/min
Supply unit
construction
With flow adjustment valve/stop valve
-
Return unit
construction
Flow switch
With flow adjustment valve
Stop valve
-
Flow switch
With flow
adjustment valve
Stop valve
Fl
u
id
Applicable fluid
Water and ethylene glycol solution with a viscosity of 3mPa
s(3 cP) or less
2
Fluid temp.
0 to 90
o
C (No freezing and condensation)
P
re
s
s
u
re
s
p
e
c
.
Operating pressure
range
3
0 to 1 MPa
Proof pressure
3
1.5 MPa
Pressure loss
Refer to graph of pressure loss
En
v
iro
n
m
e
n
t
Enclosure
IP65
Operating temp.
range
0 to 50
o
C (No freezing and condensation)
Operating humidity
range
Operation, Storage: 85%R.H. (No condensation)
Standard
CE marked (EMC directive, RoHS directive)
Materials in contact with
fluid
PPS, SUS304, FKM
Grease free
P
ip
in
g
p
o
rt
s
iz
e
4
Main piping
1
Attachment
3/8, 1/2, 3/4
1: When the flow range of 40 (rated flow range: 5 to 40 L/min) is selected in the supply/return unit, it is possible to mount 5 stations at a
maximum.
2: Please refer to the chart of measurement range of ethylene glycol aqueous solution on page
. Measurement is possible as long as
the fluid does not corrode the wetted parts, and viscosity is 3mPa
s (3 cP) or less. Be aware that water leakage may happen due to
internal seal shrinkage or swelling depending on kinds of fluid.
3: The operating pressure range and proof pressure vary depending on the fluid temperature. Refer to the chart on page
4: If a reduced piping diameter or the piping layout cause a restriction, it may not satisfy the specifications.
:
The form of the G thread (including the major and minor diameter and pitch of the internal thread) is based on JIS B0202 (ISO228-1).
Products indicated as ISO1179-1 (G thread for hydraulics) or ISO16030 (G thread for pneumatics) are based on JIS B0202
(ISO228-1) for effective depth of thread, seat surface area, surface roughness and squareness.
For ISO1179-1 (G thread for hydraulics), the withstand pressure is specified for each product. SMC do not guarantee the withstand
pressure specified in ISO1179-1, ISO1179-2, ISO1179-3, or ISO1179-4.
For ISO16030 (G thread for pneumatics), the withstand pressure is specified for each product. SMC do not guarantee the withstand
pressure specified in ISO16030.
5: Any products with tiny scratches, smears, or display colour variation or brightness which does not affect the performance are verified
as conforming products.
Summary of Contents for PF3W504
Page 12: ...11 No PF OMW0004 A Model Indication and How to Order Integrated type Basic type...
Page 13: ...12 No PF OMW0004 A Integrated type Straight type...
Page 14: ...13 No PF OMW0004 A Remote type Supply type...
Page 15: ...14 No PF OMW0004 A Remote type Return type...
Page 55: ...54 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 56: ...55 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...
Page 58: ...57 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 59: ...58 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...