-29-
No.PF
※※
-OMW0004-A
■
Wiring
Wiring of connector
Connections should only be made with the power supply turned off.
Use separate routes for the Flow switch wiring and any power or high voltage wiring. Otherwise, malfunction
may result due to noise.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply. When a switch-mode power supply is connected to the product, switching noise will be
superimposed and the product specification can no longer be met. This can be prevented by inserting a
noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the
product, or by using a series power supply instead of a switch-mode power supply.
Integrated display type (PF3W7)/Remote type sensor (PF3W5)
Pin No
Integrated display type (PF3W7)
Remote type sensor (PF3W5)
Lead wire colour
1
DC(+)
DC(+)
Brown
2
OUT2
N.C./temp. analogue output
White
3
DC(-)
DC(-)
Blue
4
OUT1
Flow rate analogue output
Black
When PF3W7 (IO-Link) is used
SIO mode setting
Pin No
Name
Lead wire colour
Function
1
DC(+)
Brown
12 to 24 VDC
2
N.C./OUT2
White
Not connected/Switch output 2 (SIO)
3
DC(-)
Blue
0 V
4
OUT1
Black
Switch output 1
IO-Link mode setting
Pin No
Name
Lead wire colour
Function
1
L+
Brown
18 to 30 VDC
2
N.C./OUT2
White
Not connected/Switch output 2 (SIO)
3
L-
Blue
0 V
4
C/Q
Black
Communication data (IO-Link)/Switch output 1 (SIO)
: When using the lead wire with M8 connector included with the PF3W7 series.
Tighten the connector by hand.
Summary of Contents for PF3W504
Page 12: ...11 No PF OMW0004 A Model Indication and How to Order Integrated type Basic type...
Page 13: ...12 No PF OMW0004 A Integrated type Straight type...
Page 14: ...13 No PF OMW0004 A Remote type Supply type...
Page 15: ...14 No PF OMW0004 A Remote type Return type...
Page 55: ...54 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 56: ...55 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...
Page 58: ...57 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 59: ...58 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...