-45-
No.PF
※※
-OMW0004-A
Model
PF3W704
PF3W720
PF3W740
Display method
2-screen display (main screen, sub screen)
Main screen: 4-digit, 7-segment, 2-colour; red/green
Sub screen: 9-digit, 11-segment (5
th
digit is 7-segment only), White
Display updating frequency 5 times/sec.
Indicator light
Output 1 and 2: Orange
Po
wer
s
u
p
p
ly
v
o
lt
a
g
e
Used as switch
output device
12 to 24 VDC, including ripple (p-p) 10%
Used as IO-Link
device
18 to 30 VDC, including ripple (p-p) 10%
Current consumption
50 mA max.
Digital filter
6
Select from 0.5 s/1.0 s/2.0 s/5.0 s/10.0 s/15.0 s/20.0 s/30.0 s
E
n
v
ir
o
n
m
e
n
t
Enclosure
IP65
Operating temp.
range
0 to 50
o
C (No freezing and condensation)
Operating humidity
range
Operation, Storage: 35 to 85%R.H. (No condensation)
Withstand voltage
7
1000 VAC, for 1 minute between the terminals and housing
Insulation
resistance
50 MΩ min. (with 500 VDC) between the terminals and housing
Standards and regulations
CE marked (EMC directive, RoHS directive)
Material of fluid contact
parts
PPS, SUS304, FKM
Grease free
Com
m
u
n
ic
a
ti
o
n
s
p
e
c
.
(Duri
n
g
I
O
-L
in
k
m
o
d
e
)
IO-Link type
Device
IO-Link version
V1.1
Communication
speed
COM2 (38.4 kbps)
Min. cycle time
3.5 ms
Process data length
Input Data: 6 byte, Output Data: 0 byte
On request data
communication
Available
Data storage
function
Available
Event function
Available
Vendor ID
131(0x0083)
Device ID
8
L(2):
352(0x0160)
L(2)T:
357(0x0165)
L(2):
353(0x0161)
L(2)T:
358(0x0166)
L(2):
354(0x0162)
L(2)T:
359(0x0167)
Summary of Contents for PF3W504
Page 12: ...11 No PF OMW0004 A Model Indication and How to Order Integrated type Basic type...
Page 13: ...12 No PF OMW0004 A Integrated type Straight type...
Page 14: ...13 No PF OMW0004 A Remote type Supply type...
Page 15: ...14 No PF OMW0004 A Remote type Return type...
Page 55: ...54 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 56: ...55 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...
Page 58: ...57 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Page 59: ...58 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...