-95-
No.PF
※※
-OMY0005
Error name
Error display
Description
Measures
Accumulated flow
error
The accumulated value has
exceeded the accumulated flow
range.
(For accumulated increment)
Reset the accumulated flow.
(Press the DOWN and SET buttons
simultaneously for 1 second or longer)
The accumulated value has reached
the set accumulated value.
(For accumulated decrement)
Zero clear error
A pressure of 7%F.S. or more is
applied during the zero clear
operation.
(Return to measurement mode in
one second)
Select the suitable IO-Link version for
the device.
Version does not
match
Version of master and IO-Link
does not match.
Align the master IO-Link version to the
device.
: If the error cannot be reset after the above measures are taken, or errors other than above are displayed, please contact SMC.