background image

16 

 

 

Piping and Operation 

 

Caution 

Mounting posture of the pump is set with the mounting foot facing downward. Maintain the proper 
tightening torque for fittings and mounting bolts, etc. Looseness can cause problems such as fluid 
and air leaks, while over tightening can cause damage to threads and parts, etc. 
 

  Starting and Stopping    Refer to circuit example (1) 

1. Connect air piping 

Note 1)

 to the pilot air supply port <P1>, <P2> and connect piping for the fluid to 

be transfered to the suction port <FLUID IN> and the discharge port <FLUID OUT>. 

2. Using a regulator, set the pilot air pressure within the range of 0.1 to 0.5 MPa. Then, the pump 

operates when power is applied to the solenoid valve 

Note 2)

 of the pilot air supply port and fluid 

flows from the suction port <FLUID IN> to the discharge port <FLUID OUT>. At this time, the 
throttle on the discharge side is in an open state. The pump performs suction with its own power 
even without priming. (Dry state suction lifting range: up to 0.5m) To restrict exhaust noise, attach 
a silencer to the solenoid valve air exhaust port. 

3. To stop the pump, exhaust the air pressure being supplied to the pump with the solenoid valve of 

the air supply port. 

 
Note 1) When used for highly permeable fluids, the solenoid valve may malfunction due to the gas 

contained in the exhaust. Implement measures to keep the exhaust from going to the 
solenoid valve side. 

Note 2) For the solenoid valve, use an exhaust center 5 port valve. If air in the drive chamber is not 

released when the pump is stopped, the diaphragm will be subjected to pressure and its life 
will be shortened. 

 

  Discharge Flow Rate Adjustment   

1. The flow rate from the discharge port <FLUID OUT> can be adjusted easily by changing the 

switching cycle of the solenoid valve on the air supply port.

 

   
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Circuit example (1) 

Circuit example (2) 

 

Recommended Valve 

VQZ24

0 (Exhaust center) 

 

Summary of Contents for PA5013

Page 1: ...Doc no PAB OMY0027 PRODUCT NAME Process Pump MODEL Series Product Number PA5013...

Page 2: ...ons P 2 to 3 Names and functions of parts P 4 Precautions P 5 to 9 Applicable Fluids P 10 Specifications P 11 Performance Curve P 12 to 14 Working Principle P 15 Maintenance Parts P 15 Piping and Oper...

Page 3: ...nt failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The asse...

Page 4: ...ts 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product...

Page 5: ...ion piping Discharge port FLUID OUT Discharges the fluid taken in the pump Connect discharge piping Pilot air supply port P1 P2 Supplies air of set pressure Connect the air piping Foot Holds the produ...

Page 6: ...uch as rubber hose or an accumulator to absorb the impact pressure 4 Liquid seals To ensure that fluid does not become sealed inside the process pump when stopping the pump relieve the discharge press...

Page 7: ...ide the cracking pressure should be 0 02 MPa or less 2 Mounting Caution 1 Read the operation manual before mounting the product Read the operation manual carefully and understand the contents before m...

Page 8: ...nt or as supply air testing under user s operating conditions is recommended 5 Operating environment Warning 1 Do not use in the following environments as this can cause failure 1 Locations with an at...

Page 9: ...ice life of diaphragm and maintenance of consumable items If the operating cycle of the process pump exceeds the service life of diaphragm the diaphragm may be damaged due to deterioration If it is da...

Page 10: ...ump Adjust the volume by operating the valve 6 When the discharge volume is large flow speed is high depending on the fluid type and operating conditions there will be cavitation leading to a poor ope...

Page 11: ...ditions be sure to check it by means of experimentation 6 Compatibility is indicated for fluid temperatures specified for the respective products 60 C or less 7 These may be penetrated by fluids and t...

Page 12: ...d areas PP Diaphragm PTFE Check valve PTFE PP PFA Liquid contact seals FFKM Fluid Refer to P 11 for applicable fluids Discharge rate 1 to 45 L min 1 to 50 L min Average discharge pressure 0 to 0 4 MPa...

Page 13: ...ection procedures 1 First mark the intersection point for a discharge rate of 15 L min and a discharge pressure of 0 14 MPa 2 Find the pilot air pressure for the marked point In this case cycle 3 Hz t...

Page 14: ...edures 1 Look up from the 4 Hz switching cycle to find the intersection with SUP 0 4 MPa 2 From the point just found draw a line to the Y axis to find the air consumption The result is approximately 2...

Page 15: ...y is 100 mPa s and the discharge rate is 12 L min Since this is equivalent to 68 of the discharge rate for fresh water 12 L min 0 68 17 6 L min indicating that a discharge rate of 17 6 L min is requir...

Page 16: ...d is performed by repeating this process with the control of an external solenoid valve 5 port valve Maintenance Parts It is not recommended to disassemble the process pump However if this is necessar...

Page 17: ...on the discharge side is in an open state The pump performs suction with its own power even without priming Dry state suction lifting range up to 0 5m To restrict exhaust noise attach a silencer to th...

Page 18: ...17 Dimensions...

Page 19: ...da Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the...

Reviews: