- 6 -
2. Through-hole Mounting
Model
Bolt
Tightening torque (N
・
m)
L(mm)
MXZ12
M3x0.5
0.63
24.5
MXZ16
M3x0.5
25.5
MXZ20
M3x0.5
29.7
MXZ25
M3x0.5
32.2
(2) How to mount the workpiece
Mounting to the Table Using the Tapped Holes
Model
Bolt
Tightening torque
(N
・
m)
Min. screw-in
depth (mm)
Max. screw-in
depth [mm]
MXZ12
M3x0.5
0.63
5
6
MXZ16
M3x0.5
5
6
MXZ20
M3x0.5
5.5
6.3
MXZ25
M3x0.5
6.5
8.3
Caution
1) If bolts are too long, they will come into contact with the bracket or flange during retraction, this wi
l l lead to the guide malfunction. Do not use bolts that are over the maximum screw-in depth in
length.
2) When tightening the screws into the table surface, be careful to prevent applying a torque to the
guide.