![background image](http://html1.mh-extra.com/html/smc-networks/mxz12-series/mxz12-series_operation-manual_1299840012.webp)
- 12 -
2-7 Auto Switch Mounting
Precautions for mounting
Caution
1) Auto switch mounting tool
For the tightening of the mounting screws (attached to the auto switch), use a watchmaker's
screwdriver with a handle diameter of about 5 to 6 mm.
2) Tightening torque
0.05 to 0.15N
・
m
As a guide, turn an additional 90 degrees from the position where it feels tight.
■Tightening Torque
Tightening Torque for Auto Switch Mounting Screw (N
・
m)
Auto switch model
Tightening torque
D-M9 (V)/M9 W(V)
0.05 to 0.15
3) Please refer the table below for proper mounting position of the auto switch (when the stroke end
is detected).
For the setting of the auto switch, make adjustment checking the actual operating condition.
Minimum Stroke for Auto Switch Mounting
Auto switch
model
Mounring
D-M9
□V
D-M9
□WV
D-M9
□AV
D-M9
□
D-M9
□W
D-M9
□A
(1) Bottom mounting
5
10 *2)
15 *1)
15 *1)
(2) When mounting an auto switch
into the groove from the top*3)
15
15
30
30
(3)When mounting the autoswitch
into the groove through the
mounting surface.
5
10 *2)
5
10 *2)
*1) For 5 and 10 mm strokes, lead wires will interfere with mounting surface.
*2) For 5 mm stroke, it is possible to mount an auto switch, but 2-color display may not be available.