![SMC Networks MSQB1 Operation Manual Download Page 31](http://html1.mh-extra.com/html/smc-networks/msqb1/msqb1_operation-manual_1300525031.webp)
Auto switch proper mounting position at rotation end
Table 11
Auto Switch Rotation range / Actuation /
most sensitive position
Size
Rotation
(deg)
Solid state switch
D-M9 Auto switch
D-F8 Auto switch
A
(mm)
Operation
range
θm
(deg)
Hysteresis
range
(deg)
B
(mm)
Operation
range
θm
(deg)
Hysteresis
range
(deg)
1
190
20.9
49
10
16.9
20
10
2
190
22.8
50
10
18.8
20
10
3
190
24.4
47
10
20.4
15
10
7
190
28.7
31
10
24.7
15
10
Operating range
θm: The value in which the auto switch operating range “Lm” is
converted to axis rotating value.
Hysteresis range : Value of auto switch hysteresis converted to an angle.
Note) The above values are only provided as a guideline, and they are not guaranteed.
In the actual setting, adjust them after confirming the auto switch operating condition.
- 30 -
Fig. 9
Magnet
Most sensitive position
Operation range at
optimum set position (Lm/2)
Auto switch
operating range Lm
D-M9
D-F8
A
A
A
A
B
B
B
B
2020-10-13 10:38
DI987004