![SMC Networks MSQB1 Operation Manual Download Page 23](http://html1.mh-extra.com/html/smc-networks/msqb1/msqb1_operation-manual_1300525023.webp)
Mounting
Load restrictions
Set the load and moment to be applied to the table within the allowable values shown in the table below.
(Values exceeding the allowable range will cause excessive play, reduce accuracy, and shorten service
life.)
Table 4. Allowable load
Size
Allowable radial load
(
N
)
Allowable thrust load
(
N
)
Allowable moment
(
N
・
m
)
(
a
)
(
b
)
Basic type
High precision
type
1
31
41
41
0.56
0.84
2
32
45
45
0.82
1.2
3
33
48
48
1.1
1.6
7
54
71
71
1.5
2.2
Unit used as flange mount
Rotary table can be mounted from three directions-Two side of axial direction and one side of lateral face.
Mounting axial direction
Mounting in lateral side
Mounting on the top
Mounting at bottom
Mounting on lateral side
Table 5. Bolt size for mounting on axial direction
Size
Bolt
Mounting on the top
Mounting at bottom
Bolt
Tap depth
When using body tap
When using body through hole
1
M3×0.5
3.5
M4×0.7
M3
2
3
M5×0.8
M4
7
M4×0.7
4.5
Table 6. Mounting on lateral side
Size
Bolt
Tap depth
1
M4×0.7
4
2
3
7
M5×0.8
5
- 22 -
(
a
)
(
b
)
2020-10-13 10:38
DI987004