Mounting of auto switch
Use a watchmaker’s screwdriver of grip diameter 5 to 6mm
to tighten the auto switch mounting screws to a tightening
torque of D-M9
:0.05 to 0.15N
・
m, D-A9
:0.10
~
0.20 N
・
m.
Use the designated slotted set screws.
Proper auto switch mounting position at rotation end
Table 13
Auto Switch Rotation range / Actuation /
most sensitive position
Size
Rotation
Reed switch
Solid state switch
A
B
Operation
range
θm
Hysteresis
range
A
B
Operation
range
θm
Hysteresis
range
10
190°
27
45
53°
10° or less 31
49
37°
5° or less
20
190°
35
62
50°
10° or less 39
66
33°
5° or less
30
190°
39
68
43°
10° or less 43
72
29°
5° or less
50
190°
49
83
33°
10° or less 53
87
22°
5° or less
70
190°
54
95
30°
10° or less 58
99
21°
5° or less
100
190°
61 108
27°
10° or less 65 112
18°
5° or less
200
190°
81 139
21°
10° or less 85 143
15°
5° or less
Operating range θm: Value of the operating range Lm of a single auto switch converted
to an axial rotation angle.
Hysteresis range : Value of auto switch hysteresis converted to an angle.
Note) The above values are only provided as a guideline, and they are not guaranteed.
In the actual setting, adjust them after confirming the auto switch operating condition.