![SMC Networks JXC51 Operation Manual Download Page 25](http://html1.mh-extra.com/html/smc-networks/jxc51/jxc51_operation-manual_1299614025.webp)
- 24 -
No.JXC
※
-OMX0011-A
5. PWR: Power supply plug
5.1 Power supply plug specifications
The specifications of the power plug supplied with the controller are shown below.
Power supply plug
Pin
No.
Terminal
Function
Descriptions
1
C24V
Control power (+)
The positive control power.
2
M24V
Motor power (+)
The positive power for the electric
actuator motor to be supplied via
the controller.
3
EMG
Stop signal (+)
The positive power for Stop signal.
4
0V
Common power (-)
The negative common power for
M24V, C24V, EMG and LK RLS.
5
-
NC
Not connected.
6
LK RLS
Lock release (+)
The positive power for lock release.
Equivalent to Phoenix Contact: FMC1,5/3-ST-LR
5.2 Electric wire specifications
Prepare the wiring according to the following specifications (to be prepared by the user).
Item
仕様
Applicable wire size
Single, stranded wire
⇒
AWG20 (0.5mm
2
)
The rated temperature for the insulation coating: 60
o
C or more,
Cable sheath O.D. ø2.5mm or less
Stripped section length
Caution
Multiple electric wires should not be connected to one terminal.
Arrange wiring so that conductors of each terminal do not contact other lines.
After wiring the power supply plug, connect it to PWR power connector of the controller.
Refer to
5.3. Power supply plug
for wiring.
8mm
2.5mm
or less
Power supply
plug
to PWR
To PWR
Power plug