4
How to use
-101-
No.PS
※※
-OMW0009-A
●
Product individual parameters (continued)
Index
Sub
index
Access
1
Items
Data
type
2
Initial value
Data
storage
3
Set value
Remarks
dec
hex
1250 0X04E2
1
R/W
OUT
p
o
rt
p
re
ssu
re
(
OU
T
1
)
Output mode
U8
1
Y
0: HYS
1: Wind
Setting of OUT1 output mode
2
R/W
Output type
U8
0
Y
0: Normal output
1: Reverse
output
Setting of OUT1 output normal and
reserved output
1260 0X04EC
1
R/W
HYS mode set value
S16
300
Y
-200 ~ 2200
Setting of OUT1 output set value
2
R/W
HYS mode hysteresis
S16
50
Y
0 ~ 2400
Setting of OUT1 hysteresis
3
R/W
Wind mode lower
limit set value
S16
250
Y
-200 ~ 2200
Setting of OUT1 output set value
(lower limit of window comparator)
4
R/W
Wind mode upper
limit set value
S16
500
Y
-200 ~ 2200
Setting of OUT1 output set value
(upper limit of window comparator)
5
R/W
Wind mode hysteresis
S16
50
Y
0 ~ 1200
Setting of OUT1 hysteresis
(window comparator hysteresis)
6
R/W
ON delay time
U16
100
Y
0 ~ 6000
Setting of OUT1 delay time at ON
0.01 s increment (0 to 60 s)
7
R/W
OFF delay time
U16
100
Y
0 ~ 6000
Setting of OUT1 delay time at OFF
0.01 s increment (0 to 60 s)
1450 0X05AA
1
R/W
OUT
p
o
rt
p
re
ssu
re
(
OU
T
2
)
Output mode
U8
1
Y
0: HYS
1: Wind
Setting of OUT2 output mode
2
R/W
Output type
U8
0
Y
0: Normal output
1: Reverse
output
Setting of OUT2 output normal and
reversed output
1460 0X05B4
1
R/W
HYS mode set value
S16
300
Y
-200 ~ 2200
Setting of OUT2 output set value
2
R/W
HYS mode hysteresis
S16
50
Y
0 ~ 2400
Setting of OUT2 hysteresis
3
R/W
Wind mode lower
limit set value
S16
250
Y
-200 ~ 2200
Setting of OUT2 output set value
(lower limit of window comparator)
4
R/W
Wind mode upper
limit set value
S16
500
Y
-200 ~ 2200
Setting of OUT2 output set value
(upper limit of window comparator)
5
R/W
Wind mode hysteresis
S16
50
Y
0 ~ 1200
Setting of OUT2 hysteresis
(window comparator hysteresis)
6
R/W
Delay time ON
U16
100
Y
0 ~ 6000
Setting of OUT1 delay time at ON
0.01 s increment (0 to 60 s)
7
R/W
Delay time OFF
U16
100
Y
0 ~ 6000
Setting of OUT1 delay time at OFF
0.01 s increment (0 to 60 s)
1470 0X05BE
1
R/W
Ot
h
e
r
o
u
tp
u
t
(O
U
T
2
)
Output mode
U8
2
Y
2: Err
3: OFF
Selection of output mode when the
OUT2 hardware output is set to
"others"
2
R/W
Output type
U8
0
Y
0: Normal output
1: Reverse
output
Summary of Contents for ISA3-F series
Page 10: ...2 About this product 9 No PS OMW0009 A With control unit ...
Page 23: ...2 About this product 22 No PS OMW0009 A ISA3 Without control unit DIN rail mounting ...
Page 24: ...2 About this product 23 No PS OMW0009 A ISA3 B L1 3 5 7 With control unit Bracket mounting ...
Page 25: ...2 About this product 24 No PS OMW0009 A ISA3 B R1 3 5 7 ISA3 B R0 2 4 6 8 ISA3 B LN ISA3 B RN ...
Page 42: ...3 Installation 41 No PS OMW0009 A Part structure Without control unit ...
Page 43: ...3 Installation 42 No PS OMW0009 A With control unit Supply port Left side ...
Page 44: ...3 Installation 43 No PS OMW0009 A With control unit Supply port Right side ...
Page 115: ...5 Troubleshooting 114 No PS OMW0009 A Relationship between supply pressure and display ...