4
How to use
-99-
No.PS
※※
-OMW0009-A
●
Product individual parameters
Index
Sub
index
Access
1
Items
Data
type
2
Initial value
Data
storage
3
Set value
Remarks
dec
hex
1000 0X03E8
0
R/W
Display unit
U8
0
Y
0: kPa
1: bAr
2: psi
Setting of display unit
1010 0X03F2
0
R/W
Display colour
U8
2
Y
0: red
1: Grn
2: 1SoG
3: 1Sor
4: 2SoG
5: 2Sor
Setting of display colour
1020 0X03FC
0
R/W
SW output PNP/NPN
selection
U8
1
Y
0: nPn
1: PnP
Setting of switch output
specification
1400 0X0578
0
R/W
OUT2 hardware output
U8
2
Y
0: Distance
1: SUP port
pressure
2: OUT port
pressure
3: Other
1210 0X04BA
1
R/W
Di
st
a
n
ce
(
OU
T
1
)
Output mode
U8
0
Y
0: HYS
1: Wind
Setting of OUT1 output mode
2
R/W
Output style
U8
1
Y
0: Normal output
1: Reverse
output
Setting of OUT1 output normal and
reserved output
1220 0X04C4
1
R/W
HYS mode set value
S16
Refer to
Table "SW
output
default
value".
Y
Refer to
"Distance
measurement
value set
range".
Setting of OUT1 output set value
2
R/W
HYS mode hysteresis
S16
Y
Setting of OUT1 hysteresis
3
R/W
Wind mode lower
limit set value
S16
Y
Setting of OUT1 output set value
(lower limit of window comparator)
4
R/W
Wind mode upper
limit set value
S16
Y
Setting of OUT1 output set value
(upper limit of window comparator)
5
R/W
Wind mode hysteresis
S16
Y
Setting of OUT1 hysteresis
(window comparator hysteresis)
1410 0X0582
1
R/W
Di
st
a
n
ce
(
OU
T
2
)
Output mode
U8
0
Y
0: HYS
1: Wind
Setting of OUT2 output mode
2
R/W
Output style
U8
1
Y
0: Normal output
1: Reverse
output
Setting of OUT2 output normal and
reversed output
1420 0X058C
1
R/W
HYS mode set value
S16
Refer to
Table "SW
output
default
value".
Y
Refer to
"Distance
measurement
value set
range".
Setting of OUT2 output set value
2
R/W
HYS mode hysteresis
S16
Y
Setting of OUT2 hysteresis
3
R/W
Wind mode lower
limit set value
S16
Y
Setting of OUT2 output set value
(lower limit of window comparator)
4
R/W
Wind mode upper
limit set value
S16
Y
Setting of OUT2 output set value
(upper limit of window comparator)
5
R/W
Wind mode hysteresis
S16
Y
Setting of OUT2 hysteresis
(window comparator hysteresis)
Summary of Contents for ISA3-F series
Page 10: ...2 About this product 9 No PS OMW0009 A With control unit ...
Page 23: ...2 About this product 22 No PS OMW0009 A ISA3 Without control unit DIN rail mounting ...
Page 24: ...2 About this product 23 No PS OMW0009 A ISA3 B L1 3 5 7 With control unit Bracket mounting ...
Page 25: ...2 About this product 24 No PS OMW0009 A ISA3 B R1 3 5 7 ISA3 B R0 2 4 6 8 ISA3 B LN ISA3 B RN ...
Page 42: ...3 Installation 41 No PS OMW0009 A Part structure Without control unit ...
Page 43: ...3 Installation 42 No PS OMW0009 A With control unit Supply port Left side ...
Page 44: ...3 Installation 43 No PS OMW0009 A With control unit Supply port Right side ...
Page 115: ...5 Troubleshooting 114 No PS OMW0009 A Relationship between supply pressure and display ...