4
How to use
-80-
No.PS
※※
-OMW0009-A
OUT2 output check
Press the UP or DOWN button to select OUT2 output
check.
Distance switch output 1
Press the UP or DOWN button to select
forcibly output ON/OFF to check the
output condition.
: Bit offset: 0 in the process data will change to 0 (Forcibly output OFF)/
1 (Forcibly output ON).
Press the SET button to set.
Distance switch output 2
Press the UP or DOWN button to select
forcibly output ON/OFF to check the
output condition.
: Bit offset: 1 in the process data will change to 0 (Forcibly output OFF)/
1 (Forcibly output ON).
Press the SET button to set.
In the SIO mode, when the SET
button is pressed, the screen
will return to the output check
screen.
To finish this mode, return the
output to [n] (normal output) and
press the SET button. Then the
mode will return to function
selection mode.
In IO-Link communication mode, press the
SET button to move on the next confirmation.
During the IO-Link communication, it is possible
to check the process data output operation.
Summary of Contents for ISA3-F series
Page 10: ...2 About this product 9 No PS OMW0009 A With control unit ...
Page 23: ...2 About this product 22 No PS OMW0009 A ISA3 Without control unit DIN rail mounting ...
Page 24: ...2 About this product 23 No PS OMW0009 A ISA3 B L1 3 5 7 With control unit Bracket mounting ...
Page 25: ...2 About this product 24 No PS OMW0009 A ISA3 B R1 3 5 7 ISA3 B R0 2 4 6 8 ISA3 B LN ISA3 B RN ...
Page 42: ...3 Installation 41 No PS OMW0009 A Part structure Without control unit ...
Page 43: ...3 Installation 42 No PS OMW0009 A With control unit Supply port Left side ...
Page 44: ...3 Installation 43 No PS OMW0009 A With control unit Supply port Right side ...
Page 115: ...5 Troubleshooting 114 No PS OMW0009 A Relationship between supply pressure and display ...