5. Troubleshooting

 

 

 

5 - 1

 

 

 

 

 

 

5.1 Troubleshooting 

If any error is found in the product, investigate the following points. If the error cannot be solved, turn off the 

power supply and contact your local supplier or SMC sales representative. 

Trouble 

Possible cause 

Remedy 

Although the 
switch with lamp 
is turned on, the 
lamp does not 
light up and the 
product does not 
start operating. 

The power supply cable has been 
loosened or disconnected. 

- Reconnect it firmly. 

The ground fault circuit 
interrupter is not turned on. 

Check the capacity of the ground fault circuit interrupter. 
- Check the product was not restarted within 3 minutes after 

being stopped. 

-  Turn  on  the  ground  fault  circuit  interrupter  and  try  to 
operate. 

If the ground  fault  circuit  interrupter turns back off, the 
insulation failure of the product is suspected. Turn off the 
power supply and contact SMC. 

Running lamp 

extinguishes   

and compressor 

stops during 

operation but 

resumes normal   
operation   
illuminating the 
lamp after 
aperiod of time. 

The  product  is  installed  in  an 
inappropriate location. 
Ambient temperature is excessive. 

-  Improve  ventilation  condition  and  reduce  the  ambient 

temperature as much as possible. 

The  ventilation  port  is  obstructed 
by a wall or clogged with dust. 

- Keep the product 60cm or more away from the surrounding 

walls. 

- Clean the ventilation ports once every month. 

The compressed air temperature is 
too high. 

-  Improve  the  ventilation  in  the  location  where  the  air 

compressor  is  installed,  or  decrease  the  ambient 
temperature to allow the discharge air temperature of the 
air compressor to go down. 

- Install an aftercooler after the air compressor to reduce the 

temperature. 

The fluctuation of the power supply 
voltage is too large. 
 

- Install a power supply transformer or use a different power 

supply to provide appropriate voltage. 

- The fluctuation of the power supply voltage should be kept 

/-10% of the rated voltage. 

The evaporation 
thermometer is 
over the green 
area without hot 
air coming from 
the ventilation   
port (exhaust 
port). 
(The compressor 
for refrigeration 
has stopped  with 
the lamp lit up. 

The  product  is  installed  in  an 
inappropriate location. 
Ambient temperature is excessive. 

-  Improve  ventilation  condition  and  reduce  the  ambient 

temperature as much as possible. 

The  ventilation  port  is  obstructed 
by a wall or clogged with dust. 

- Keep the product 60cm or more away from the 
surrounding walls. 
- Clean the ventilation ports once every month. 

The compressed air temperature is 
excessive. 

-  Improve  the  ventilation  in  the  location  where  the  air 

compressor  is  installed,  or  decrease  the  ambient 
temperature to allow the discharge air temperature of the 
air compressor to go down. 

- Install an aftercooler after the air compressor to reduce the 

temperature. 

The fluctuation of the power supply 
voltage is too large. 
 

- Install a power supply transformer or use a different power 

supply to provide appropriate voltage. 

- The fluctuation of the power supply voltage should be kept 
/-10% of the rated voltage. 

The  built-in  overload  relay  of  the 
compressor  for  refrigeration  has 
started. 

- Check the product was not restarted within 3 minutes after 

being stopped. 

Troubleshooting 

5 

Summary of Contents for IDU15E1-10

Page 1: ...20 C K L M R T Keep this manual available whenever necessary 2016 SMC CORPORATION All Rights Reserved This manual is intended to explain the installation and operation of the product Only people who u...

Page 2: ...systems 2 JIS B 8370 General rules for pneumatic equipment This manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the produ...

Page 3: ...Chapter 1 Name and Function of Parts 1 1 Name and function of parts 1 1 Chapter 2 Transportation and installation 2 1 Transportation 2 1 2 2 Installation 2 2 2 2 1 Environment 2 2 2 2 2 Fixing of pro...

Page 4: ...1 9 3 Installation of heavy duty auto drain 9 2 9 4 Maintenance 9 2 Chapter 10 Specification for Option M 10 1 Safety instructions 10 1 10 2 Specifications 10 1 10 3 Installation of motor type auto d...

Page 5: ...g without having sufficient knowledge about safety is very dangerous Training must not be conducted without consideration to safety This manual must be kept available to the operator whenever necessar...

Page 6: ...of hazard labels The product has various potential hazards and they are marked with warning labels Read this section before starting any work on the product Warning Only trained personnel should hand...

Page 7: ...product is operated at a high voltage and contains the power supply isolated by the cover panel Do not operate the product without cover panels fitted Only people who have sufficient knowledge and ex...

Page 8: ...other unexpected accidents i 2 6 Location of hazard label Warning Fully read and understand the contents of the hazard labels Do not peel or rub off the hazard labels Carefully confirm where the haza...

Page 9: ...uct is serviced the refrigerant must be recovered using refrigerant recovery equipment and disposed of by a specialist disposal company Only people who have sufficient knowledge and experience about t...

Page 10: ...ard labels are affixed i 2 9 Other labels Confirm the model and specifications described in the label Front CAUTION 1 Read manual before operation 2 Ensure vantilation and maintenance space 3 Keep wat...

Page 11: ...er the refrigerant Only maintenance personnel or people who have sufficient knowledge and experience are allowed to open the cover panels of the product The type and necessary amount of HFC can be fou...

Page 12: ...Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products Compliance Requirements 1 The use of SMC products...

Page 13: ...erature of refrigerant Normally it is in the green area Drain tube Discharges drain Auto drain It is covered with insulator which should not be removed Front panel removal Drain confirmation window Fr...

Page 14: ...let piping A port to supply air IDU15E1 10 100V AC specification Front Earth screw Connect the earth to this screw Power supply cable Insert the plug to a 100V AC only outlet IDU15E1 20 200V AC specif...

Page 15: ...ct The product is filled with refrigerant Transport it by land sea or air in accordance with laws and regulations specified You should lift the product from the base surface with careful attention to...

Page 16: ...that is subjected to potential lightning strikes Locations by loading on vehicles marine vessels and so on In a location with an altitude of 2 000 metres or higher In a location where the product is...

Page 17: ...ere is not enough space around the ventilation ports of the product loss of the original performance or failure of the product can result Follow the conditions shown in the figure below for installati...

Page 18: ...to the compressed air source to the product Use a pipe capable of withstanding the specified operating pressure and temperature and connect so that it will not have leakage Be sure to install a bypass...

Page 19: ...supply of the prodct Wiring of power supply There are two methods depends on model specified power IDU15E1 10 100V AC specification Insert the power plug into an outlet of AC100V Be sure to install a...

Page 20: ...duct in a different location Also be sure to follow the instructions below When moving the product to a different location or reinstalling it after it has been used including trial run follow the whol...

Page 21: ...ompressed air inlet and outlet valve 3 Unscrew the front panel fixing screw in 2 points and remove the front panel with upholding it a little 4 Open the residual pressure release cock of auto drain tu...

Page 22: ...d bypass of the product are completely closed 3 2 Start Start the product by the following procedure 1 Turn on the main power supply Then turn on the switch with lamp 2 The lamp will light up and the...

Page 23: ...activated If operation cannot be restarted refer to Chapter 5 Troubleshooting to solve it 3 5 Check items after starting Check the following items when starting the product Immediately stop the opera...

Page 24: ...very month Wear protective goggles and a mask to prevent dust from entering the eyes or throat during air blow 4 2 2 Service parts It is recommended to replace the following parts regularly The interv...

Page 25: ...e sure to switch off the earth leakage breaker installed before starting work As some parts of the air dryer will remain hot there is a risk of burns due to residual heat after the power is switched o...

Page 26: ...g for damage such as scratches twisting or foreign particles attached to it Then apply grease thinly and fit it in the groove in the case assembly Fit the auto drain strainer to the case assembly and...

Page 27: ...se the ambient temperature to allow the discharge air temperature of the air compressor to go down Install an aftercooler after the air compressor to reduce the temperature The fluctuation of the powe...

Page 28: ...ressor to go down Install an aftercooler after the air compressor to reduce the temperature Moisture is generated at the downstream of the compressed air line The bypass valve is open Be sure to fully...

Page 29: ...pplicable ground fault circuit interrupter capacity Note 4 A 10 Refrigerant R134a HFC Quantity of refrigerant g 350 10 Auto drain Float type N O Port size Rc1 Weight kg 71 Coating color Panel Urban wh...

Page 30: ...TILATION 620 300 VENTILATION VENTILATION 425 43 66 4x 13 LENGTH 0 8m LENGTH 1 9m AC100V POWER SUPPLY CORD 470 VENTILATION 14 330 358 DRAIN TUBE DRAIN SEPARATOR VENTILATION O D 10 960 Symbol Descriptio...

Page 31: ...outlet Refrigerant circuit The HFC gas contained in the refrigerant circuit is compressed by the compressor and cooled and liquefied by the condenser When passing through the capillary tube the HFC ga...

Page 32: ...th aluminum fins and insulations are not painted 7 3 Precautions for the installation and handling of the product 1 The surface of cooper tube is painted with a special epoxy to improve the rust proof...

Page 33: ...ves to prevent contact with the drained condensate When oils can enter the drained condensate waste water treatment is necessary Follow the bylaws or rules of the local municipality for disposal 8 2 S...

Page 34: ...contact with the drained condensate When oils can enter the drained condensate waste water treatment is necessary Follow the bylaws or rules of the local municipality for disposal 9 2 Specifications T...

Page 35: ...fitting width across flats 22 to drain port width across flats 27 and the drain tube 9 4 Maintenance 1 As a preventive maintenance press the flush button of the heavy duty auto drain regularly to cle...

Page 36: ...es of the local municipality for disposal Warning Only qualified persons are allowed to wire the product Use a power supply suitable for the specifications of the product Be sure to connect the ground...

Page 37: ...flats 30 and the drain tube 4 Connect the 2 electric cables coming out from the auto drain with the two electric cables from the dryer unit Insert the drip proof connector to the deepest part 10 4 El...

Page 38: ...power supply 11 2 Specifications Customer should connect power cords at primary side of ground fault circuit interrupter which is different from standard such as plug in type AC100V or terminal block...

Page 39: ...button white pressed Over current 2 Check the operation once a month by pressing the test button gray with the breaker on and Switch with Lamp off 11 5 Electric wiring diagram IDU15E1 10 R IDU15E1 20...

Page 40: ...ould never be connected to a water line gas line or lightning rod Multiple wiring is dangerous because it may lead to heat generation and cause a fire Do not modify the electrical wiring of the power...

Page 41: ...cription CM Refrigerating compressor FM1 Fan motor FM2 Fan motor OLR Overload relay ILS Switch with lamp PTC PTC Starter PRS Pressure switch TB Terminal block CR CR Unit C01 Capacitor for running refr...

Page 42: ...ire Do not modify the electrical wiring of the power supply For use in Europe install a breaker compliant with applicable IEC standards to the power supply of the prodct 13 2 Specifications This optio...

Page 43: ...the terminal 4 Insert the signal cable prepared by the customer into the signal cord inlet with rubber grommet and bring the signal cable near the terminal block 5 Connect the signal cable to the each...

Page 44: ...FM1 FM2 C11 C12 MC CR MC P PRS TDR CM ILS Symbol Description Symbol Description CM Refrigerating compressor C01 Capacitor for running refrigerating compressor FM1 Fan motor C02 Capacitor for starting...

Reviews: