2. Transportation and installation
2 - 6
Terminal block
(refer to “1.1 Name and function of parts” for details).
Connect the power cable and the ground to the terminal block. The connection size is M3.
Be sure to use a round crimped terminal.
Applicable crimped terminal width: 6.5mm or less
[Wiring procedure]
1. Remove the terminal block cover or the rear panel.
2.
Insert the cord through the rubber grommet and connect it to the terminal block (refer to the label on the
terminal block).
M3 screw tightening torque: 0.63 to 1Nm
During wiring work, do not touch other sections except terminal block.
3. Re-attach the cover or real panel after wiring is done.
2.3 Reinstallation of the product
Caution
- Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to reinstall the product in a different location. Also, be sure to
follow the instructions below.
When moving the product to a different location or reinstalling it after it has been used (including trial run),
follow the whole procedure in Chapter 2 beforehand.
- Disconnection of power supply cable
Be sure to cut the facility power supply before disconnecting the power supply cable.
Removal of pneumatic piping
Clean off any sealant debris after the piping is removed. If any sealant debris gets into the product during
reinstallation, it may lead to cooling failure or other product failures.
Warning
- Only people who have sufficient knowledge and experience are allowed to perform wiring.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
Warning
- Only people who have sufficient knowledge and experience are allowed to perform piping work.
- Before removing piping, be sure to shut off the air supply and the product.
- Do not remove piping with any air pressure remaining internally.