IDX-OM-W022
Air Dryer
10 Specification for Option M
10-3 Installation of motor type auto drain
10- 3
IDU Series
10-3 Installation of motor type auto drain
1) Hold the hexagon-head part at port Rc1/2 of the air dryer with spanner.
Then install nipple, ball valve (width across flats: 25).
Note 1) Put up the seal tape or the sealant to the nipple. Torque R1/2: 28 to 30Nm
2) Hold the ball valve with the spanner. Then install a nipple and a motor type auto drain.
Install with “out port" down in a vertical position. Inclination from the vertical line should be less than 5°.
3) Install one-touch fitting (width across flats: 17) to drain port (width across flats: 30) and the drain tube.
4) Connect the 2 electric cables coming out from the auto drain with the two electric cables from the dryer
unit. Insert the drip-proof connector to the deepest part.
10-4 Electric
circuit
For details of the electric circuit, refer to the label on the back of the front panel of this product (see page 1-1).
motor type auto drain
drip-proof connector
ball valve
nipple
port Rc1/2 of the air dryer