IDX-OM-W022
Air Dryer
6 References
6-1 Specifications
6 - 1
IDU Series
6 References
6-1 Specifications
Model
Specification
IDU8E-10/20 IDU11E-10/20 IDU15E1-10/20
Rated Cond
ition
Air Flow Rate
m
3
/min (ANR)(Note 1)
50Hz
1.1 1.5 2.6
60Hz
1.2 1.7 2.8
Operating Pressure
0.7MPa
Inlet Air Temperature
55
o
C
Ambient Temperature
32
o
C
Pressurized Dew Point
10
o
C
Operating
Range
Working Fluid
Compressed Air
Inlet Air Temperature
5 ~ 80
o
C
Inlet Air Pressure
0.15 ~ 1.0MPa
Ambient Temperature
2 ~ 40
o
C(Relative Humidity of 85% or less)
E
lec
tr
ic
al
S
p
eci
fic
a
tio
n
Power source
100VAC(50/60Hz)
Single phase AC100/100 , 110V
[
Voltage fluctuations
±
10%
]
200VAC(50/60Hz)
Single phase AC200/200 , 220V
[
Voltage fluctuations
±
10%
]
Operating urrent
(Note 2) A
100VAC(50/60Hz) 3.4/3.5
5.7/6.0
4.6/4.9
200VAC(50/60Hz) 1.7/1.7
3.5/3.2
3.6/3.4
Power
consumption
(Note 2) W
100VAC,200VAC
(50/60Hz)
250/290 425/470 460/530
Circuit Breaker
(Note 3)
100VAC 10A
200VAC 5A
10A
Condenser
Plate fin tube type with forced air cooling
Refrigerant R134a
(HFC)
Refrigerant Charge(AC100V/200V) g
280
±
5 290
±
5 350
±10
Drain Connection
Rc3/4
Rc1
Drain Connection
10mm
Coating Color
Panel: Urbanwhite 1
Base: Urbangray 2
Weight kg
44
47
71
Applicable Compressor(Standard) kW
7.5
11
15
Note1: The data for m
3
/min (ANR) is referring to the conditions of 20
°
C, 1atm. pressure & relative humidity of
65%.
Note 2: The value is that of under specified condition.
Note 3: Install GFCI breaker with sensivity of
30mA.
Note 4: When short period power shortage (including instantly recovered shortage) is recovered, it may take a longer starting