IDX-OM-W022
Air Dryer
2 Transportation / Installation
2-2 Installation
2
-
2
IDU Series
2-2 Installation
2 - 2 - 1 Location
The product should not be used or stored in the circumstances as follows.
Those circumstances will cause not only malfunction but also failures.
•
Environment where the product is exposed to
rainwater, moisture vapor, salty water, oil and
so on.
•
Locations where dust or particles are.
•
Locations where inflammable or
explosive gas are.
•
Locations where corrosive gas, solvent,
combustible gas are.
•
Locations that receive direct sunlight or where
radiant heat is generated.
•
Locations
where
ambient temperature is
beyond following range:
On-stream: 2 to 40
o
C
Storage: 0 to 50
o
C (when there is no
drain water inside of the piping)
•
Locations
where
temperature changes rapidly.
•
Locations
where
strong
•
electromagnetic noise is generated (locations
where electromagnetic field,
strong magnetic field, surge is
generated)
•
Circumstances where static electricity is
produced or discharged through the body of the
product.
•
Locations where strong high frequency wave is
generated.
•
Locations where danger of thunder is apparent.
•
Locations by loading on vehicles,
marine vessels, and so on.
•
Locations whose altitude is higher than 2,000
meters.
•
Circumstances where strong vibration or
impact are transmitted.
•
Circumstances where too much force and
weight are put on the body of the product that
causes it to deform.
•
Circumstances where enough spaces cannot
be taken to do maintenance (in the plant where
the product is operated).
Spaces needed for maintenance
Front : 600 mm
Rear
: 600 mm
Top
: 600 mm
Right : 600 mm
Left
: 600 mm
•
Locations
the
ventilation grille of the product
can be blocked.
•
Place where rejection style air of air
compressor or other driers (hot wind) is
inhaled.
•
Condition which has sudden pressure/flow rate
changes.
Warning
Do not use and store in environment having compressed air or ambinet atmosphere which
includes the following substances. It could result in failure of the product and damage of
components, which leads to injury.
- Corrosive gas, Organic solvent, Chemicals
2 - 2 - 2 Anchorage
•
The air dryer should be installed on a vibration-free, stable, horizontal flat surface.
•
Refer to “Chapter6 6-3 Dimensions” for the dimensions.
•
Fix by bolts to prevent falling down. The bolts can be prepared separately as an accessory.
Model No.
Name
Quantity
Applicable Model
IDF-AB500
Anchor bolt set
1(4pcs
/
1set
)
IDU8E to ID15E