6 References
6 - 1
6 References
6-1
Specifications
Model
Specification
IDFB22E-11
□
IDFB22E-23
□
IDFB37E-23
□
IDFB55E-46
□
IDFB75E-46
□
At Expected Outlet
Press.Dew Point of 37
°
F
(
2.8
℃
)
107SCFM
(182 m
3
/h)
161SCFM
(273 m
3
/h)
226SCFM
(384 m
3
/h)
300SCFM
(510 m
3
/h)
At Expected Outlet
Press.Dew Point of 45
°
F (7.2
℃
)
120SCFM
(205 m
3
/h)
173SCFM
(294 m
3
/h)
258SCFM
(438 m
3
/h)
353SCFM
(600 m
3
/h)
Air
F
lowRate
(ANR)(Note 1)
At Expected Outlet
Press.Dew Point of 50
°
F (10
℃
)
130SCFM
(221 m
3
/h)
181SCFM
(308 m
3
/h)
297SCFM
(504 m
3
/h)
406SCFM
(690 m
3
/h)
Operating Pressure
100psig (0.7MPa)
Inlet Air Temperature
100
°
F (37.8
℃
)
Ambient Temperature
100
°
F (37.8
℃
)
Rated
Condit
ion
Voltage
115V 60Hz
230V 60Hz
460V 60Hz
Working Fluid
Compressed Air
Inlet Air Temperature
40-122
°
F (5-50
℃)
MIN.Inlet Air Pressure
22psig
(
0.15MPa
)
MAX.Inlet Air Pressure
150psig
(
1.0MPa
)
Operating
Range
Ambient Temperature
36-104
°
F (2
〜
40
℃
) Relative Humidity of 85% or less
Power Source
1
φ
AC115V
±
10% 60Hz
(Note4)
1
φ
AC230V
±
10% 60Hz (Note4)
3
φ
AC460V
±
10% 60Hz (Note4)
Starting Current and LRA (Note2)
42A
26A
30A
27A
Operating Current (Note2)
9A
4.5A
5.6A
3.8A
Power Consumption (Note2)
1000W
1270W
2400W
E
lec
tr
ic
al
S
p
e
cificat
ion
Circuit Breaker Capacity (Note3)
15A
10A
Condenser
forced air cooling
Refrigerant R134a(HFC)
R407C(HFC)
Refrigerant Charge Quantity
18.7
±
0.4oz
(530
±
10g)
25.7
±
0.4oz
(730
±
10g)
15.2
±
0.4oz
(430
±
10g)
20.8
±
0.4oz
(590
±
10g)
Thread Symbol “N”
(male)
NPT1 NPT1-1/2 NPT2
Thread Type
and Size
Thread Symbol “None”
(male)
R1 R1-1/2 R2
Thread Symbol “N”
3/8inch
Drain Tube
Thread Symbol “None”
10mm
Painting Finish
baking finish
Colour
Panel : Urbanwhite1
Weight
119lbs
(54kg)
137lbs
(62kg)
258lbs
(117kg)
271lbs
(123kg)
Note1: The data for SCFM (ANR) is referring to the conditions of 68
°
F (20
°
C), 1atm . pressure & relative
humidity of 65%.
Note 2: The value is that of under specified condition.
Note 3: Install GFCI breaker with sensivity of
30mA.
Note 4: When short period power shortage (including instantly recovered shortage) is recovered, it may take
a longer starting period than usual starting or may not start due to the protective devices.